8 Technical Specifications
Pellux 100 boiler
PBMAX burners
Technical parameters
Unit
PBMAX 20.1
PBMAX 30
Burner capacity
kW
6 ÷ 20 kW
9 ÷ 30 kW
Fuel
mm
Ø 6 ÷ 10 / max. length 30
Power supply
V
1/N/PE 230 V, 50 Hz
Electric power
W
40
Electric power at start-up
W
650
Degree of protection
-
IP 21
Net weight
kg
14,5
17
Technical parameters
Unit
PELLUX 100/20
(K-PAA 20)
PELLUX 100/30
(K-PAA 30)
Boiler class
-
5
5
Rated power
kW
20
30
Net weight
kg
202
245
Water capacity
l
60
70
Power supply
V
1/N/PE 230 V, 50 Hz
Boiler efficiency
%
90 - 92
Boiler temperature range
°C
60-80
Operating temp max
°C
85
Return temp min (at the boiler inlet)
°C
45
Flue gas temp
°C
80 ÷ 150
Noise level
dB
48 dB
Outlet
mm
ø127
Pressure max
MPa (bar)
0.25 (2.5)
Flue gas draught required
Pa
18 ÷ 20
20 ÷ 40
Length of combustion chamber
mm
320 mm
Degree of protection
-
IP 21
Chimney diameter
mm
130-160
Chimney height (recommended)
m
7 m
8 m
Power consumption in standby mode
W
13 W
Power consumption at nominal power
W
43 W
54 W
Power consumption at min power
W
20 W
26 W
Flue gas mass flow – at rated power
kg/h
42 kg/h
64 kg/h
Flue gas mass flow – at min power
kg/h
18 kg/h
28 kg/h
Pressure drop at the boiler – Δ10 °C
mbar
2
(1)
mbar
6
(2)
mbar
Pressure drop at the boiler – Δ20 °C
mbar
6
(3)
mbar
17
(4)
mbar
(1) at Q = 0,8 m3/h, (2) at Q = 1,3 m3/h, (3) at Q = 1,6 m3/h, (4) at Q = 2,5 m3/h