General
This manual contains instructions about how the
Contura 655/685 must be constructed and installed.
Instructions for lighting and use are also supplied
with the stove. Read them carefully and keep them
safe for future use.
The stove is type approved and must be connected
to a chimney dimensioned for at least 350°C; the
external connection diameter is Ø150 mm.
Supply air from the open air should be used as
combustion air.
Technical specifications
Output
3 – 9 kW
Nominal output
6 kW (approx. 1.5 kg/hour)
Efficiency, up to
80%
655
685
Weight (kg)
150
150
Width (mm)
550
550
(foot Ø580)
Depth (mm)
480
480
(foot Ø580)
Height (mm) 1200 1260
Connector ext.
Ø150 mm
Type approved in accordance with:
European standard EN-13240 class 1
Swedish environmental and quality marking,
P-marking cert. no. 22 03 06
Swedish type approval, cert.no. 0388/01
Norwegian standard NS 3059, Cert. No. 043-104
German standard DIN 18.891, RO-91 01 319
Danish standard 887-1, id no 598
Building permission
It. may. be. necessary. for. you. to. apply. for. building.
permission.from.your.local.planning.authority.before.
installing. a. stove. or. erecting. a. chimney .. Before.
starting.installation.work,.make.sure.that.you.check.
which.regulations.apply .
Structural support
Check.to.make.sure.that.the.floor.is.strong.enough.
to. support. the. weight. of. the. stove. and. chimney .. If.
you.intend.to.locate.the.stove.on.standard.wooden.
floor. joists,. contact. a. professional. builder. to. make.
sure.that.the.construction.will.withstand.the.load ..If.
the.total.weight.does.not.exceed.400.kilos,.it.is.not.
usually.necessary.to.reinforce.the.joists ..
Floor plate
To.protect.the.floor.from.sparks.and.falling.embers.
the.stove.must.stand.on.a.non-combustible.surface.
which. extends. at. least. 300. mm. in. front. of. the.
stove. and. 100. mm. along. each. side .. As. other.
statutory.requirements.apply.in.some.countries,.we.
recommend. that. you. consult. the. relevant. authority.
or.an.authorised.chimney-sweep.in.your.area .
Chimney
The stove requires a draft in the chimney of at least
–12 Pa. The draught is affected both by the length
and area of the chimney, and by how well sealed it is.
Minimum recommended chimney length is 3.5 m and
a suitable cross section area is 150-200 cm² (140-
160 mm in diameter).
Carefully check that the chimney is sealed and that
there is no leakage around soot hatches and flue
connections.
Note that a flue with sharp bends and horizontal
routing reduces the draught in the chimney. Maximum
horizontal flue is 1 m, on the condition that the vertical
flue length is at least 5 m.
It must be possible to sweep the full length of the flue
and the soot hatches must be easily accessible.
Fire-bars
Grate.disc
Cast-iron.fire-bed
Smoke.baffle
Fire-box.surround
Ash-pan.