12
NIBE
TM
AP-BW30
We reserve the right to make technical changes
83053706dUK – Translation of the operating manual
INSTALLING THE HOUSING
NOTE.
Remove the protective film from all facing panels.
NOTE.
The screws for installing the heat pump housing
are included in the scope of delivery.
Position the insulation included in the scope of
delivery under the baseplate.
NOTE.
Before screwing on the side panels, feed the patch
cable and + LIN bus cable through the rear panel!
see “electrical connection work”
Screw the two side panels onto the back panel using
3 screws for each:
Mount the profile rail onto the front of the unit,
between the two side panels, using 2 screws for
each side.
1 Profile rail
2 Screw
Align the facing with the baseplate as shown in the
following sketch
28
28
28
Secure and fix the facing on the profile rail using the
fastening materials included in the scope of delivery
(2 x 10mm anchors and 2 x M8 hanger bolts). Twist
the hanger bolt into the floor up to the start of the
thread.
1 hanger bolt with anchor
Align the insulating board under the unit with the
middle of the unit (see ).
Fix the housing cover onto the rear panel (5 screws):
and the two side panels (2 screws each) onto the
front: