nextys PSH150 Скачать руководство пользователя страница 2

 

 
 

PSH150

 user manual rev4 

Page 2/15 

 

 

 

DISCLAIMER 

 

 

NEXTYS

  reserves  the  right  to  make  changes  without  further  notice  to  any  products  herein. 

NEXTYS

 

makes  no  warranty,  representation  or  guarantee  regarding  the  suitability  of  its  products  for  any 
particular purpose, nor does 

NEXTYS

 assume any liability arising out of the application or use of any 

product,  and  specifically  disclaims  any  and  all  liability,  including  without  limitation  consequential  or 
incidental  damages.  “Typical"  parameters  which  may  be  provided  in 

NEXTYS

  data  sheets  and/or 

specifications can and do vary in different applications and actual performance may vary overtime. All 
operating  parameters,  including  “Typicals",  must  be  validated  for  each  customer  application  by 
customer's  technical  experts. 

NEXTYS

  does  not  convey  any  license  under  its  patent  rights  nor  the 

rights of others. 

NEXTYS

 products are not designed, intended, or authorized for use as components in 

systems  intended  for  surgical  implant  into  the  body,  or  other  applications  intended  to  support  or 
sustain  life,  or  for  any  other  application  in  which  the  failure  of  the 

NEXTYS

  product  could  create  a 

situation where personal injury or death may occur. Should Buyer purchase or use 

NEXTYS

 products 

for any such unintended or unauthorized application, Buyer shall indemnity and hold 

NEXTYS

 and its 

officers,  employees,  subsidiaries,  affiliates,  and  distributors  harmless  against  all  claims,  costs, 
damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim 
of personal injury or death associated with such unintended or unauthorized use, even if such claim 
alleges that 

NEXTYS

 was negligent regarding the design or manufacture of the part.  

 
The Customer should ensure that it has the most up to date version of the document by contacting its 
local 

NEXTYS

  office.  This  document  supersedes  any  earlier  documentation  relating  to  the  products 

referred to herein. The information contained in this document is current at the date of publication. It 
may subsequently be updated, revised or withdrawn. 
 
The Customer should ensure that 

NEXTYS

 product uses the most up to date Software and Firmware 

provided on 

NEXTYS

 website to ensure reliable operation of the system. 

 
All  Trade  Marks  recognized.  Specifications  and  information  herein  are  Subject  to  change  without 
notice. 
 
 

Содержание PSH150

Страница 1: ...PSH150 user manual rev4 Page 1 15 PSH150 10kV Isolation Programmable Power Supply User Manual POWERMASTER...

Страница 2: ...ication in which the failure of the NEXTYS product could create a situation where personal injury or death may occur Should Buyer purchase or use NEXTYS products for any such unintended or unauthorize...

Страница 3: ...atures and benefits 5 3 Functional description 6 3 1 Main DC output 7 3 2 Auxiliary 12V output 8 3 3 INHIBIT input 8 3 4 Display interface 8 3 4 1 Normal operation 8 3 4 2 Menu navigation 9 3 4 3 Alar...

Страница 4: ...custom application Firmware update is also possible 4 INHIBIT input A voltage between 5Vdc and 30Vdc applied to this input activates the inhibit function 3 3 5 Auxiliary 12Vdc output This output provi...

Страница 5: ...control and monitoring Multiple protections Can be paralleled for power or redundancy integrated ORing circuitry Up to 50 C operating temperature with no derating Wall mount fixing possible Suitable...

Страница 6: ...y power supply of 12V 100mA is available An external INHIBIT signal can be applied for controlling the output status A multifunctional display shows the output parameters and 3 keys can be used for pr...

Страница 7: ...derating curves are reported Current Derating Curve 0 2 4 6 8 10 12 14 40 30 20 10 0 10 20 30 40 50 60 70 80 Temperature C Current A 5V 12V 24V 48V Figure 3 PSH150 current derating curves Power Derati...

Страница 8: ...ED display used to indicate the status and to navigate through the configuration menus During normal operation the output parameters are reported 3 4 1 Alarms and error codes are also reported on the...

Страница 9: ...us addess 5s No store 2s Set Set Store Set 5s Output Voltage Modbus baudrate 5s No store 2s Set Set Store Set 5s Output Voltage Modbus stop bits 5s 2s Set Set Store Set 5s Output Voltage Modbus parity...

Страница 10: ...al fault V A W USB power no mains available The product is powered through USB and the input mains is not present The user can navigate through the menus It can be used for firmware upgrade without th...

Страница 11: ...put voltage Output current 0x2001 8193 Input register 3 4 Measured output current Output power 0x2002 8194 Input register 3 4 Measured output power Auxiliary voltage 0x2003 8195 Input register 3 4 Mea...

Страница 12: ...rne Ne pas essayer de r parer ou modifier le produit si des d faillances se produisent pendant le fonctionnement ou les dysfonctionnements le retourner au fabricant pour inspection Nextys SA n assume...

Страница 13: ...adjacent devices as specified in the I S manual of each family DIN rail mounting 1 Pull down to release and unlock the slide clamps 2 Tilt the unit slightly backwards 3 Fit the unit over the top edge...

Страница 14: ...or 0 337 lbf Input output connections Solid 2 5mm 12AWG Stranded 1 5mm 12AWG L 6 0 7 5mm 0 24 0 30in Auxiliary connections Solid 0 5mm 20AWG Stranded 0 5mm 20AWG L 7 0 8 0mm 0 27 0 315in Input connect...

Страница 15: ...designed according to the latest Reference standards if not expressly indicated through the official documents or files they have been tested through our internal pre compliance testing Consult direct...

Отзывы: