nextys PSH150 Скачать руководство пользователя страница 12

 

 
 

PSH150

 user manual rev4 

Page 12/15 

 

4   Installation 

READ THIS CAREFULLY BEFORE INSTALLATION! 

LEGGERE ATTENTAMENTE PRIMA 

DELL’INSTALLAZIONE!

 

A LIRE ATTENTIVEMENT AVANT L’INSTALLATION!

 

Before operating, read this document thoroughly and 

retain it for future reference. 

Non-respect of these instructions may reduce 

performances and safety of the devices and cause danger 

for people and property. 

The products must be installed, operated, serviced and 

maintained by qualified personnel in compliance with 

applicable standards and regulations. 

Don’t open the device, it does not contain replaceable 

components, the tripping of the internal fuse (if included) is 

caused by an internal failure.  

Don’t repair or modify the device, if malfunction or failure 

should occur during operation, send unit to the factory for 

inspection. No responsibility is assumed by Nextys SA for 

any consequences deriving from the use of this material. 

Prima dell’installazione, leggere attentamente questo 

documento istruzioni e conservarle per future consultazioni.  

L’inosse

rvanza delle presenti istruzioni può compromettere le 

caratteristiche e la sicurezza dell’apparecchio e causare 

pericolo per le persone e le cose. 

Il prodotto deve essere installato, utilizzato e riparato da 

personale qualificato e nel rispetto delle normative vigenti.  

Non aprire il prodotto, esso non contiene componenti 

sostituibili, il guasto del fusibile interno (se previsto) è causato 

da un guasto interno. Non tentare di riparare o modificare il 

prodotto, se durante il funzionamento si verificano guasti o 

anomalie, inviarlo al produttore per il controllo. 

Nextys SA non si assume nessuna responsabilità per 

qualunque conseguenza derivante dall’uso di questo materiale.

 

Lisez ces instructions avant l'installation, conservez ce 

manuel pour référence future.  

Défaut de se conformer à ces instructions peut affecter les 

caractéristiques et la sécurité du dispositif de danger et de 

causer aux personnes ou aux biens. 

Les produits doivent être installés, exploité et entretenus par 

personnel qualifié et en conformité avec les règlements. 

N'ouvrez pas le produit, il ne contient aucune pièce 

réparable, le déclenchement du fusible interne (le cas 

échéant) est causé par un défaut interne. Ne pas essayer de 

réparer ou modifier le produit ; si des défaillances se 

produisent pendant le fonctionnement ou les 

dysfonctionnements, le retourner au fabricant pour 

inspection. Nextys SA n'assume aucune responsabilité des 

conséquences éventuelles découlant de l'utilisation des 

produits.

 

CAUTION 

ATTENZIONE 

AVVERTISSEMENT

 

RISK OF BURNS, EXPLOSION, FIRE, ELECTRICAL 

SHOCK, PERSONAL INJURY. 

Never carry out work on live parts! Danger of fatal injury! 

The product’s enclosure may be hot, allow time for cooling 

product before touching it. Do not allow liquids or foreign 

objects to enter into the products.  

To avoid sparks, do not connect or disconnect the device 

before having previously turned-off input power and wait 

for internal capacitors discharge (minimum 1 minute). 

RISCHIO USTIONI, ESPLOSIONE, INCENDIO, SCOSSA, 

LESIONI GRAVI. 

Non effettuare mai operazioni sulle parti sotto tensione! 

Pericolo di lesioni letali! Il contenitore può scottare, lasciar 

quindi raffreddare il dispositivo prima di toccarlo. Non far 

entrare liquidi o oggetti estranei nel dispositivo. 

Per evitare scintille, non collegare o scollegare 

l'apparecchiatura prima di avere tolto tensione di ingresso e 

prima che sia avvenuta la scarica dei condensatori interni (min. 

1 minuto). 

RISQUE DE BRULURES, EXPLOSION, INCENDIE, 

ELECTROCUTION, DOMMAGE AUX PERSONNES. 

Ne jamais effectuer des opérations sur les parties sous 

tension! Danger de mort! Le récipient peut produire des 

brulures, le laisser refroidir avant de toucher l'appareil. Ne 

faites pas pénétrer des liquides ou des corps étrangers dans 

l'appareil. Pour éviter des étincelles, ne pas connecter ou 

déconnecter l'équipement jusqu'à ce que vous avez 

supprimé la tension d'entrée et avant qu'elle n'ait lieu de 

décharge des condensateurs internes (minimum 1 minute).

 

 

Connections 

 

 

1. 

AC input 

2. 

USB-B Type 

communication port 

3. 

RS-485 communication 

port 

4. 

DC output (load) 

5. 

INHIBIT 

6. 

Auxiliary 12Vdc 

7. 

DC OK dry contact 

8. 

UP button menu 

9. 

SET button menu 

10. 

DOWN button menu 

11. 

Display 

 

Input Connection: 

 

Single Phase 

 

L = Line 

 

N = Neutral 

 

Input DC 

 

L = Positive DC 

 

N = Negative DC 

 

Output Connection: 

 

 

+ = Positive DC 

 

- = Negative DC 

 

Signaling: 
 

INHIBIT 

(5…30Vdc)

 

 

+ = Positive DC 

 

- = Negative DC 

 

12V AUX 

(12Vdc / 100mA) 

 

12V+ = Positive DC 

 

12V- = Negative DC 

 

Dry contact: 

 

COM 

 

NO 

 

NC 

RS-485 

 

 

 

PIN4 = TX/RX D1 

 

PIN5 = TX/RX D0 

 

PIN8 = GND 

USB-B Type

 

 

 

1 = VBUS (+5V) 

 

2 = Data (D-) 

 

3 = Data (D+) 

 

4 = GND 

Dimensions 

Distances 

 

 

Dimension 


mm 

179.5 

100.3 

64.5 

Distance

 

B

 

mm

 

20 

50

 

Содержание PSH150

Страница 1: ...PSH150 user manual rev4 Page 1 15 PSH150 10kV Isolation Programmable Power Supply User Manual POWERMASTER...

Страница 2: ...ication in which the failure of the NEXTYS product could create a situation where personal injury or death may occur Should Buyer purchase or use NEXTYS products for any such unintended or unauthorize...

Страница 3: ...atures and benefits 5 3 Functional description 6 3 1 Main DC output 7 3 2 Auxiliary 12V output 8 3 3 INHIBIT input 8 3 4 Display interface 8 3 4 1 Normal operation 8 3 4 2 Menu navigation 9 3 4 3 Alar...

Страница 4: ...custom application Firmware update is also possible 4 INHIBIT input A voltage between 5Vdc and 30Vdc applied to this input activates the inhibit function 3 3 5 Auxiliary 12Vdc output This output provi...

Страница 5: ...control and monitoring Multiple protections Can be paralleled for power or redundancy integrated ORing circuitry Up to 50 C operating temperature with no derating Wall mount fixing possible Suitable...

Страница 6: ...y power supply of 12V 100mA is available An external INHIBIT signal can be applied for controlling the output status A multifunctional display shows the output parameters and 3 keys can be used for pr...

Страница 7: ...derating curves are reported Current Derating Curve 0 2 4 6 8 10 12 14 40 30 20 10 0 10 20 30 40 50 60 70 80 Temperature C Current A 5V 12V 24V 48V Figure 3 PSH150 current derating curves Power Derati...

Страница 8: ...ED display used to indicate the status and to navigate through the configuration menus During normal operation the output parameters are reported 3 4 1 Alarms and error codes are also reported on the...

Страница 9: ...us addess 5s No store 2s Set Set Store Set 5s Output Voltage Modbus baudrate 5s No store 2s Set Set Store Set 5s Output Voltage Modbus stop bits 5s 2s Set Set Store Set 5s Output Voltage Modbus parity...

Страница 10: ...al fault V A W USB power no mains available The product is powered through USB and the input mains is not present The user can navigate through the menus It can be used for firmware upgrade without th...

Страница 11: ...put voltage Output current 0x2001 8193 Input register 3 4 Measured output current Output power 0x2002 8194 Input register 3 4 Measured output power Auxiliary voltage 0x2003 8195 Input register 3 4 Mea...

Страница 12: ...rne Ne pas essayer de r parer ou modifier le produit si des d faillances se produisent pendant le fonctionnement ou les dysfonctionnements le retourner au fabricant pour inspection Nextys SA n assume...

Страница 13: ...adjacent devices as specified in the I S manual of each family DIN rail mounting 1 Pull down to release and unlock the slide clamps 2 Tilt the unit slightly backwards 3 Fit the unit over the top edge...

Страница 14: ...or 0 337 lbf Input output connections Solid 2 5mm 12AWG Stranded 1 5mm 12AWG L 6 0 7 5mm 0 24 0 30in Auxiliary connections Solid 0 5mm 20AWG Stranded 0 5mm 20AWG L 7 0 8 0mm 0 27 0 315in Input connect...

Страница 15: ...designed according to the latest Reference standards if not expressly indicated through the official documents or files they have been tested through our internal pre compliance testing Consult direct...

Отзывы: