CB-1450 DATA BUOY PLATFORM 

 

2091 Exchange Court 
Fairborn, Ohio 45324 
937-426-2703 
www.NexSens.com 

Safe Deployment 

Personnel safety is the number one priority when 
deploying  a  data  buoy. Use  of proper  equipment 
(work  boat,  lifting  rig,  gloves,  safety  footwear, 
etc.)  is  essential  to  safely  deploy  any  buoy 
system.  Buoy  systems  are  heavy  and  personnel 
can quickly become entangled with mooring lines 
and anchors. Safety and flotation gear should be 
worn  at  all  times  when  working  on  or  near  the 
water. 

Remember to perform a complete system test on 
shore prior to deployment. Learning the nuances 
of the system is much better handled on shore or 
in a lab rather than in the field. 

 

Specifications 

 

Hull Dimensions

: 48” (121.92cm) outside 

diameter; 28” (71.12cm) tall 

 

Tower Dimensions

: 50” (127.00cm) tall, 7/8” 

tubular 

 

Data Well Dimensions

: 12.25” (31.12cm) 

inside diameter; 55” (139.70cm) tall 

 

Weight

: 500 lbs. (226.80 kg) 

 

Buoyancy

: 1450 lbs. (657.71 kg) 

 

Hull Material

: Cross-linked polyethylene foam 

with polyurea coating & stainless steel deck 

 

Tower/Hardware Material

: 304 stainless 

steel 

 

Mooring Attachments

: 1- or 2-point, ¾” eye 

nut 

 

Solar Power

: (3) 55-watt, 12VDC solar panels 

 

Additional Information 

Additional  information  and  complete  instructions 
for  the  CB-1450  data  buoy  platforms  are 
available in the NexSens online Knowledge Base: 

 

http://www.nexsens.com/knowledge-base 
 
http://www.nexsens.com/category/knowledge-
base/data-buoys/cb-1250-buoy

 

 

 

Содержание CB-1450

Страница 1: ...dium satellite telemetry module What s Included 1 Buoy hull with data well 1450 lb buoyancy 1 Buoy tower 3 55W Solar panels 1 Data well lid iSIC CB or pass through 3 Top side lifting eyes 3 Bottom sid...

Страница 2: ...Module When the tower is ready to be mounted remove the locking pin from each of the three tower mounting hubs on top of the buoy hull Place the tower legs into the hubs and secure the locking pins F...

Страница 3: ...Communications port for iSIC data logger configuration and data acquisition through UW USB 232P NP cable or RTU R C I radio cellular or Iridium satellite telemetry module 1 SOLAR 6 pin input for sola...

Страница 4: ...inout Figure 10 UW Plug to Flying Lead Cable Pass Through Data Well Lid For applications with user supplied sensors data loggers telemetry modules and or batteries the CB 1450 data buoy is provided wi...

Страница 5: ...at connect through the SOLAR port on the data well plate to the CB A09 3 4 or user supplied battery solar regulator harness A wire lead is provided to supply 12V DC power to electronics inside the dat...

Страница 6: ...ce the buoy Conversely a ballast weight added further below the surface will provide a greater stabilizing effect than the same size weight mounted closer to the surface An instrument cage mounted to...

Страница 7: ...l mooring line connects the buoy directly to a bottom chain and anchor At normal pool stage the mooring line should be taut with most of the bottom chain resting on the floor of the water body As the...

Страница 8: ...the system is much better handled on shore or in a lab rather than in the field Specifications Hull Dimensions 48 121 92cm outside diameter 28 71 12cm tall Tower Dimensions 50 127 00cm tall 7 8 tubul...

Отзывы: