For  a  more  robust  connection  at  the  data  well 
plate,  the  pass-through  ports  may  be  fitted  with 

UW-BULK

  bulkhead  receptacle  connectors.  The 

UW-BULK

 assembly has the same pinout as iSIC-

CB  sensor  ports  (see  Table  1),  but  the  cable 
terminates  in  flying  leads  for  integration  with  a 
user-supplied  data  logger.  The  device  connected 
must have a factory-installed UW connector.

 

 

Figure 11: 

UW-Bulkhead Connector Assembly 

Solar Power Wiring 

Figure  12  shows  a  schematic  drawing  for  the 
wiring of the CB-1450 power supply. The system 
includes  (6)  30-watt  solar  panels  that  connect 
through the 

SOLAR

 port on the data well plate to 

the 

CB-A09-3/4

  or  user-supplied  battery/solar 

regulator  harness.  A  wire  lead  is  provided  to 
supply  12V  DC  power  to  electronics  inside  the 
data well (red = +12V, black = GND). 

 

Figure 12:

 

Wiring Schematic

 

 

*NOTE

:  The  12V  power  supply  leads  for  user 

supplied  electronics  will  only  supply  power  when 
the solar panel is plugged into the SOLAR port on 
the  data  well  lid,  even  if  a  battery  is  connected 
inside  the  data  well.  To  supply  battery  power 
without plugging in the solar panel, a special UW 
plug  with  internal  jumper  is  available  (P/N 

UW-

JUMPER

).

 

For systems with user-supplied battery and solar 
regulator,  the  battery  and  regulator  can  be 
connected  through  the  4-pin  Molex  connector  or 
by  cutting  the  wires  at  section  A-A  in  Figure  12 
and splicing the connections. In these situations, 
reference the signals listed in Table 2. 
 
 
 
 
 

Содержание CB-1450

Страница 1: ...dium satellite telemetry module What s Included 1 Buoy hull with data well 1450 lb buoyancy 1 Buoy tower 3 55W Solar panels 1 Data well lid iSIC CB or pass through 3 Top side lifting eyes 3 Bottom sid...

Страница 2: ...Module When the tower is ready to be mounted remove the locking pin from each of the three tower mounting hubs on top of the buoy hull Place the tower legs into the hubs and secure the locking pins F...

Страница 3: ...Communications port for iSIC data logger configuration and data acquisition through UW USB 232P NP cable or RTU R C I radio cellular or Iridium satellite telemetry module 1 SOLAR 6 pin input for sola...

Страница 4: ...inout Figure 10 UW Plug to Flying Lead Cable Pass Through Data Well Lid For applications with user supplied sensors data loggers telemetry modules and or batteries the CB 1450 data buoy is provided wi...

Страница 5: ...at connect through the SOLAR port on the data well plate to the CB A09 3 4 or user supplied battery solar regulator harness A wire lead is provided to supply 12V DC power to electronics inside the dat...

Страница 6: ...ce the buoy Conversely a ballast weight added further below the surface will provide a greater stabilizing effect than the same size weight mounted closer to the surface An instrument cage mounted to...

Страница 7: ...l mooring line connects the buoy directly to a bottom chain and anchor At normal pool stage the mooring line should be taut with most of the bottom chain resting on the floor of the water body As the...

Страница 8: ...the system is much better handled on shore or in a lab rather than in the field Specifications Hull Dimensions 48 121 92cm outside diameter 28 71 12cm tall Tower Dimensions 50 127 00cm tall 7 8 tubul...

Отзывы: