DPU
DIGITAL
PATCHING
UNIT
FOR
NXAMP
NXAMPMK2 USER MANUAL
PAGE 47 / 70
AMPLIFIER OVERTEMPERATURE LEVEL3
Amplifier temperature
reaches 80 degree:
Output is muted
(4x1/4x2)
Amplifier temperature
reaches 100 degree:
Output is muted (4x4)
Per channel limit
A. Environmental
temperature is too high
B. Unexpectedly
overloaded
Check the air flow
AMPLIFIER OVERCURRENT ALERT
Overcurrent is detected
in the given amplifier
channel
Per channel mute
The impedance of the
connected speaker might
be too low or shorten
wrongly.
Please check the speaker
connection.
HIGH LOAD ALERT
The measured
impedance is over the
predefined upper limit.
Behaves as defined in
Load Monitoring function
specification
LOW LOAD ALERT
The measured
impedance is under
the predefined upper
limit.
Behaves as defined in
Load Monitoring function
specification
DPU DIGITAL PATCHING UNIT FOR NXAMP
The Digital Patching Unit (DPU) is a 1U 1 ” accessory for NXAMP and NXAMPmk2 powered TDControllers.
This device is intended to automatically set up the power outputs of an NXAMP Powered TDController to
the correct pins on speakON 4 and speakON 8 connectors. Thus, connecting any of the NEXO speakers is
very straight forward. Moreover, it is easy to connect several DPU together in case multiple amplifiers are
needed to feed a unique speaker system.
FRONT PANEL DESCRIPTION
A: SPEAKON 4 POLES OUTPUT
There are four connectors like this on the front panel. These connectors will be used to connect any NEXO
speaker that uses the same type of connector.
A