LOG and ALERT PARAMETERS
PAGE 64 / 70
NXAMPMK2 USER MANUAL
Output voltage (per
ch.)
Peak voltage (in dBFS, 0dBFS being the
clip level of the voltage sense converter)
of a channel (accuracy of ±3dB, and
maximum rate of 25Hz). A non-null value
informs you a signal is being sent to the
output.
-60, 0 dBFS
✓
Output current (per
ch.)
Peak current (in dBFS, 0dBFS being the
clip level of the current sense converter)
of a channel (accuracy of ±3dB, and
maximum rate of 25Hz). A non-null value
informs you there is a load on the
channel.
-60, 0 dBFS
✓
Sense (per ch.)
A certain level of current is detected on
the output (a cabinet is connected, and
some sufficient signal is flowing to it).
0, 1
✓
Protection (per ch.)
Speaker protection (displacement or
thermal)
0, 1
✓
✓
Peak Limiter (per
ch.)
The peak limiter is working to protect the
amplifier for the channel.
0, 1
✓
✓
Mute (per ch.)
Mute status of a channel.
0, 1
✓
Speaker
Temperature (per
ch.)
Voice coils temperature (in dB, 0 dB being
the maximum temperature the speakers
can safely reach under the current
preset).
-60, 0 dB
✓
Speaker
Displacement (per
ch.)
Membrane displacement (in dB, 0 dB
being the maximum displacement the
speakers can safely reach under the
current preset).
-60, 0 dB
✓
Speaker Protection
(per ch.)
Reduction of the output levels currently
applied by the NXAMP (in dB, 0 dB being
no protection). It is the maximum of all
protections (displacement, thermal, peak
limiter, etc. see System Headroom for
more detail).
0, 60 dB
✓
Low and High Load
Alert (per ch.)
Should be used in conjunction with the
load monitoring function of the NXAMP
(see Load Monitoring). This function
allows sending a high frequency pilot tone
into the NXAMP and thus monitoring the
impedance of the load. If the measured
impedance for a channel goes out of the
user’s predefined limits, or if the NXAMP
cannot measure the output impedance
(no pilot tone, channel muted, and so on)
these alerts are raised.
0, 1
✓
PS overtemp
—
Power Supply
Overtemperature
(per ch.)
Abnormal temperature has been detected
by the temperature sensor on the heat
sink of the power supply.
0, 1
✓
Mains err
— Power
Supply Mains Error
(per ch.)
The mains voltage is out of the limits
(150V to 288V for the NXAMP “C” version
or the “W” version started in 2 0V mode,
and 60V to 150V for the “U” version or the
“W” version started in 120V mode).
0, 1
✓
PS volt err
— Power
Supply Output
Voltage Error (per
ch.)
The output of the power supply is out of
the limits (10V to 250V DC).
0, 1
✓