5 - Settings

The X-Dot I/O has one setting which determines the status LED behaviour of the sensor. The setting can be adjusted by 
sending X-talk setting commands via the API. After a power cycle, the setting always returns back to default.

X001S[1:1]

X001S[1:2]

X001S[1:3]

X001S[1:4]

Setting 1: Status LED behaviour

1. LED always on   

 

 

2. LED always off    

 

3. LED on when input is HIGH (def)

4. LED off when input is HIGH  

When set to 4:3, the status LED will be on when the input is 

HIGH and off when the input is LOW. Vice versa, when set 
to 4:4, the status LED will be off when the input is HIGH and 

on when the input is LOW. 

Содержание XD Series

Страница 1: ... devices 2 3 2 Controlling Output devices 2 3 3 Controlling button LEDs 3 4 Installation requirements and guidelines 3 4 1 Electrical installation requirements 3 4 2 Connection Diagrams 3 4 3 Accessories Push buttons Pressure matts Relays 4 5 Settings 6 6 Quick test 7 XDW I36 XDW I56 I O voltage 3 3V 5V Interface Input devices Interface Output devices The X Dot I O has a wire to board connector wh...

Страница 2: ... device is unactivated such as the release of a button or a pressure matt which is stepped off from Both of these states HIGH and LOW will trigger an API command 3 2 Control output devices ON OFF An Output device can be set ON or OFF When the device is set to ON the Output pin of the X Dot I O will supply 3 3V or 5V depending on the model When the device is set to OFF the Output pin will not suppl...

Страница 3: ...ot be recognized by the Xperience controller and no output will be provided 4 1 Electrical installation requirements The maximum amount of power which the Output pin can provide is 200mA In case of connecting 3rd party output devices please make sure the specifications comply Example connection to XC Controller Example connection to XN Controller 3 3 Control button LEDs A button LED is an Output d...

Страница 4: ...nnected to the pressure matt and with ferrules for easy connection to the X Dot I O The white black twisted wires should be connected to the X Dot I O for detecting when a person steps on or off the pressure matt The pressure matts are Normally open meaning that when nobody stands on the pressure matts the wires are not interconnected and the signal will be LOW When someone steps on the pressure m...

Страница 5: ...cted to the Ground terminal of the X Dot I O The AC device which is controlled by the relay should be connected to the OUTPUT terminals of the relay as indicated in the schematic on the right This should be done by a qualitifed technician according to local regulations For correct wiring color codes please check local standards When the relay is switched ON the red status LED on the relay is lit W...

Страница 6: ...LED behaviour of the sensor The setting can be adjusted by sending X talk setting commands via the API After a power cycle the setting always returns back to default X001S 1 1 X001S 1 2 X001S 1 3 X001S 1 4 Setting 1 Status LED behaviour 1 LED always on 2 LED always off 3 LED on when input is HIGH def 4 LED off when input is HIGH When set to 4 3 the status LED will be on when the input is HIGH and ...

Страница 7: ... will start to blink and once power up is completed will be lit continuously Step 2 Test Activate the Input device e g push the button Both the green status LED of the sensor and the status LED of the controller should blink For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 3 For more information on how t...

Отзывы: