4.3 X-Dot I/O - Accessories

Push buttons

Nexmosphere off ers 19mm stainless steel push buttons 

with LED ring, which are compatible with the XDW-I36. 
The partcodes for these push buttons are: 

S-B90W4S

White LED ring

S-B90B4S

Blue LED ring

S-B90G4S

Green LED ring

S-B90R4S

Red LED ring

They come with 60cm color-coded wires soldered onto 
the button, and with ferrules for easy connection to the 
X-Dot I/O. Please see the schematic on the right for the 
correct pinning.

The buttons are "Normally open", meaning that when they 
are not pressed, the wires are not interconnected and the 
signal will be LOW. When a button is pressed, the signal will 
be HIGH.  The IP Rating of the buttons is IP65.

Pressure matts

Nexmosphere off ers pressure matts which are compatible 

with the XDW-I56 and XDW-I36. The partcodes are:

S-PM6017S

595 x 170mm x 3mm

S-PM7239S

720 x 390mm x 3mm

S-PM7256S

720 x 560mm x 3mm

They come with 180cm color-coded twisted wire pairs 
connected to the pressure matt, and with ferrules for easy 
connection to the X-Dot I/O. 

The white/black twisted wires should be connected to 
the X-Dot I/O for detecting when a person steps on or 

off  the pressure matt. The pressure matts are "Normally 

open", meaning that when nobody stands on the pressure 
matts, the wires are not interconnected and the signal will 
be LOW. When someone steps on the pressure matt, the 
signal will be HIGH.

The red/black twisted wires are always interconnected, 
and when connected will therefore always generate a 
HIGH signal, regardless of whether a person stand on the 
pressure matt or not. Typically, this is used for security 
purposes, as when the wired are cut, the signal will become 
LOW. In case both options need to be utilizted, each of the 
wire pairs needs to be connected to a separate X-Dot I/O.

The pressure matts have an actuation pressure of 25KG 
over 50mm2. The IP Rating is IP64.

X001

Button is pressed

Person steps on pressure matt

No security breach (wires intact)

Button is released

Person steps off pressure matt

Security breach (wires cut)

X001A[1]

X001A[1]

X002A[1]

X001A[0]

X001A[0]

X002A[0]

API commands button input

API commands pressure matt trigger

API commands security trigger

Example API commands button LED control

Ramp from 00% brightness to 99% brightness in 1.2s

Continuously pulse from 00% to 99% brightness in 1.0s

X001B[3009912]

X001B[4009910]

X001

X001

X002

Содержание XD Series

Страница 1: ... devices 2 3 2 Controlling Output devices 2 3 3 Controlling button LEDs 3 4 Installation requirements and guidelines 3 4 1 Electrical installation requirements 3 4 2 Connection Diagrams 3 4 3 Accessories Push buttons Pressure matts Relays 4 5 Settings 6 6 Quick test 7 XDW I36 XDW I56 I O voltage 3 3V 5V Interface Input devices Interface Output devices The X Dot I O has a wire to board connector wh...

Страница 2: ... device is unactivated such as the release of a button or a pressure matt which is stepped off from Both of these states HIGH and LOW will trigger an API command 3 2 Control output devices ON OFF An Output device can be set ON or OFF When the device is set to ON the Output pin of the X Dot I O will supply 3 3V or 5V depending on the model When the device is set to OFF the Output pin will not suppl...

Страница 3: ...ot be recognized by the Xperience controller and no output will be provided 4 1 Electrical installation requirements The maximum amount of power which the Output pin can provide is 200mA In case of connecting 3rd party output devices please make sure the specifications comply Example connection to XC Controller Example connection to XN Controller 3 3 Control button LEDs A button LED is an Output d...

Страница 4: ...nnected to the pressure matt and with ferrules for easy connection to the X Dot I O The white black twisted wires should be connected to the X Dot I O for detecting when a person steps on or off the pressure matt The pressure matts are Normally open meaning that when nobody stands on the pressure matts the wires are not interconnected and the signal will be LOW When someone steps on the pressure m...

Страница 5: ...cted to the Ground terminal of the X Dot I O The AC device which is controlled by the relay should be connected to the OUTPUT terminals of the relay as indicated in the schematic on the right This should be done by a qualitifed technician according to local regulations For correct wiring color codes please check local standards When the relay is switched ON the red status LED on the relay is lit W...

Страница 6: ...LED behaviour of the sensor The setting can be adjusted by sending X talk setting commands via the API After a power cycle the setting always returns back to default X001S 1 1 X001S 1 2 X001S 1 3 X001S 1 4 Setting 1 Status LED behaviour 1 LED always on 2 LED always off 3 LED on when input is HIGH def 4 LED off when input is HIGH When set to 4 3 the status LED will be on when the input is HIGH and ...

Страница 7: ... will start to blink and once power up is completed will be lit continuously Step 2 Test Activate the Input device e g push the button Both the green status LED of the sensor and the status LED of the controller should blink For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 3 For more information on how t...

Отзывы: