Nexmosphere XD Series Скачать руководство пользователя страница 5

© 2022 Nexmosphere. All rights reserved. v1.0 / 08-28

All content contained herein is subject to change without prior notice

N ex m o s p h e re

Le   H av re   1 3 6
5 6 2 7   SW   E i n d h ove n   •   T h e   N e t h e r l a n d s

T

  + 3 1   4 0   2 4 0   7 0 7 0

E

  s u p p o r t @ n ex m o s p h e re.c o m

PRODUCT MANUAL | X-DOT I/O INTERFACE

5

Relay

Nexmosphere  off ers  a  Solid  State  Relay  (SSR)  which  is 

compatible with the XDW-I56. The partcode is:

S-RL05231

output max 230VAC/10A

It comes with a 180cm color-coded twisted wire pair 
already connected to the screw input terminals of the 
relay, and with ferrules for easy connection to the X-Dot 
I/O. 

The red wire needs to be connected to the Output terminal 

of the X-Dot I/O

. The black wire needs to be connected to 

the Ground terminal 

of the X-Dot I/O

The AC device which is controlled by the relay should 
be connected to the OUTPUT terminals 

of the relay

as indicated in the schematic on the right. This should 
be done by a qualitifed technician according to local 
regulations. For correct wiring color codes, please check 
local standards.

When the relay is switched ON, the red status LED on the  

relay is lit. When the relay is switched off , the red status 
LED will be off  as well.

Please note the S-RL05231 can only switch AC voltages 
as it switches at zero-crossing. It is not possible to switch 
DC voltages.

At start-up the output pin on the X-Dot IO will be ON per 
default, meaning that the AC device will be ON as well.

X001

AC source

phase

phase /
switch wire

neutral

AC device

(e.g. lamp)

OUTPUT

INPUT

-

+

API commands relay control

Set Relay ON
Set Relay OFF

X001A[1]

X001A[0]

Содержание XD Series

Страница 1: ... devices 2 3 2 Controlling Output devices 2 3 3 Controlling button LEDs 3 4 Installation requirements and guidelines 3 4 1 Electrical installation requirements 3 4 2 Connection Diagrams 3 4 3 Accessories Push buttons Pressure matts Relays 4 5 Settings 6 6 Quick test 7 XDW I36 XDW I56 I O voltage 3 3V 5V Interface Input devices Interface Output devices The X Dot I O has a wire to board connector wh...

Страница 2: ... device is unactivated such as the release of a button or a pressure matt which is stepped off from Both of these states HIGH and LOW will trigger an API command 3 2 Control output devices ON OFF An Output device can be set ON or OFF When the device is set to ON the Output pin of the X Dot I O will supply 3 3V or 5V depending on the model When the device is set to OFF the Output pin will not suppl...

Страница 3: ...ot be recognized by the Xperience controller and no output will be provided 4 1 Electrical installation requirements The maximum amount of power which the Output pin can provide is 200mA In case of connecting 3rd party output devices please make sure the specifications comply Example connection to XC Controller Example connection to XN Controller 3 3 Control button LEDs A button LED is an Output d...

Страница 4: ...nnected to the pressure matt and with ferrules for easy connection to the X Dot I O The white black twisted wires should be connected to the X Dot I O for detecting when a person steps on or off the pressure matt The pressure matts are Normally open meaning that when nobody stands on the pressure matts the wires are not interconnected and the signal will be LOW When someone steps on the pressure m...

Страница 5: ...cted to the Ground terminal of the X Dot I O The AC device which is controlled by the relay should be connected to the OUTPUT terminals of the relay as indicated in the schematic on the right This should be done by a qualitifed technician according to local regulations For correct wiring color codes please check local standards When the relay is switched ON the red status LED on the relay is lit W...

Страница 6: ...LED behaviour of the sensor The setting can be adjusted by sending X talk setting commands via the API After a power cycle the setting always returns back to default X001S 1 1 X001S 1 2 X001S 1 3 X001S 1 4 Setting 1 Status LED behaviour 1 LED always on 2 LED always off 3 LED on when input is HIGH def 4 LED off when input is HIGH When set to 4 3 the status LED will be on when the input is HIGH and ...

Страница 7: ... will start to blink and once power up is completed will be lit continuously Step 2 Test Activate the Input device e g push the button Both the green status LED of the sensor and the status LED of the controller should blink For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 3 For more information on how t...

Отзывы: