FORM NO. L-20179-F-1002
6
LUBRICATION
LUBRICATOR DRIP RATE SETTINGS
NOTE: These settings are for Nexen supplied lubrica-
tors. If you are not using a Nexen lubricator, calibra-
tion must replicate the following procedure.
1.
Close and disconnect the air line from the unit.
2.
Turn the Lubricator Adjustment Knob
counterclockwise three complete turns.
3.
Open the air line.
4.
Close the air line to the unit when a drop of oil
forms in the Lubricator Sight Gage.
5.
Connect the air line to the unit.
6.
Turn the Lubricator Adjustment Knob clockwise until
closed.
7.
Turn the Lubricator Adjustment Knob
counterclockwise one-third turn.
8.
Open the air line to the unit.
NOTE: Pneumatically actuated decived requre clean, pressure regulated, and lubricated air for maximum perfor-
mance and long life. The most effective and economical way to lubricate the Metric FMCB is with an Air Line
Lubricator, which injects oil into the pressurized air, forcing an oil mist into the air chamber.
Located the lubricator above and within ten feet of the Metric FMCB, and use a low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
®
DIST. AUTORIZADO
MEX (55) 53 63 23 31
QRO (442) 1 95 72 60
MTY (81) 83 54 10 18
[email protected]