Nexel HC1836HP Скачать руководство пользователя страница 2

Instruction Manual

Non-Insulated Heater/Proofer

2

INSTALLATION

Position the unit on a stable, level surface and plug in the 
supplied cord into any grounded 120VAC, 15 Amp power 
supply. It is highly recommended that you ONLY use the 
power cord supplied. Use of a dedicated circuit will help to 
ensure operational efficiency. Do not operate unit with an 
extension cord.

OPERATING INSTRUCTIONS
1.  Basic Cabinet Setup

 A. 

 

Refer to DATA PLATE for electrical requirements. 
Cabinets rated at 120V/1500W must be plugged into 
a 125VAC, 15A receptacle and must be used on an 
individual branch circuit. DO NOT MODIFY CORD 
PLUG.

 B. 

 

With POWER switch OFF, plug into 125VAC grounded 
receptacle.

 C. 

 

Fill water pan to top with clean, HOT tap water for 
proofing or holding if moisture is desired. Check water 
level every 3 hours (2 hours when proofing) and refill 
with clean HOT tap water when necessary. Water pan 
does not have to be filled for heating. Proofing requires 
water pan to be filled.

2.  Heating Instructions

 

A. Set Combination Module switch to HEAT

 B. 

 

Set POWER switch to the ON position and the power 
indicator light will turn on.

 

C. Set TEMPERATURE control to 9.

 D. 

 

Pre-heat cabinet until desired temperature is reached 
(typical heat-up time from 77°F (25°C) to 160°F (71°C) 
is approximately 45 minutes). Cabinet with insulate 
temperature reaches 185°F (85°C) in approximately 
45 minutes.

 E. 

 

Reset temperature control and adjust to desired 
temperature (setting 6-8 is typical for 150°F (66°C) to 
160°F (71°C).

3. Proofing Instructions

 

A. Set Combination Module switch to PROOF.

 B. 

 

Set POWER switch to the ON position and the power 
indicator light will turn on.

 

C. Set TEMPERATURE control to 2.

 

D. Set HUMIDITY control to 9.

 E. 

 

Pre-heat cabinet until desired temperature and humidity 
is reached (typical heat-up time from 77°F (25°C) to 
95°F (35°C) and 95% relative humidity is approximately 
30 minutes).

 F. 

 

Adjust settings to reach desired temperature and 
humidity levels.

Heat Thermostat

The controlling range is 80°F to 185°F. The dial numbers 
(1 to 9) do not relate to a specific calibrated temperature. 
Temperature settings must be obtained through familiarization 
with the unit. The dial also has an OFF position to turn heater 
unit off.

Humidity Thermostat

To control humidity range from 30% to 100%, humidity settings 
must be obtained through familiarization with the unit. The dial 
numbers (1 to 9) do not relate to a specific calibrated humidity. 
The dial also has an OFF position to turn humidity off.

NOTE: The internal air circulation blower and 1500W heater 
element (controlled with the Heat Thermostat) will operate 
continuously when the power switch is turned ON. To maintain 
low heat range between 85°F to 100°F, switch to PROOF 
mode and adjust heat knob to desired heat range. Allow 45 
minutes to per-heat in proof cycle.

MAINTENANCE

This cabinet has been designed to require minimum 
maintenance and has been constructed to meet National 
Sanitation Foundation and U.S. Public Health Service 
standards. Non-toxic chemical cleaners or mild detergents are 
recommended for cleaning of fixtures. DO NOT use steel wools 
of any kind as the wool particles will work into the grains of the 
metal causing corrosion creating a health hazard. If scouring is 
required, use a non-abrasive type of cleaner. Do not use caustic 
solutions on your equipment. Hosing or steam cleaning should 
not be necessary. Do not allow water or stem to come into 
contact with electrical components. Never power wash or stem 
clean the cabinet with the power drawer inserted.

Rated Power:

1500W, 120V, 60HZ.

2

3

1

2

3

1

4

Содержание HC1836HP

Страница 1: ...ean the cabinet wipe with a damp cloth and dry with a towel Use only cleaning agents approved for aluminum Do not wash the cabinet with a water jet or high pressure water Do not spray or pour water into the module Water dripping onto the floor from open doors can be a slip hazard Liability for improper or careless use is the responsibility of the equipment owner or persons servicing the unit inclu...

Страница 2: ...ITY control to 9 E Pre heat cabinet until desired temperature and humidity is reached typical heat up time from 77 F 25 C to 95 F 35 C and 95 relative humidity is approximately 30 minutes F Adjust settings to reach desired temperature and humidity levels Heat Thermostat The controlling range is 80 F to 185 F The dial numbers 1 to 9 do not relate to a specific calibrated temperature Temperature set...

Страница 3: ...tabs the wires will short out on the metal causing permanent damage Both the element and main power switch with wires on switch must be replaced 6 If the temperature on the L E D thermometer is not reading a constant temperature it must be replaced along with the power supply transformer Recommended Temperature Guidelines Chart Food Product F Covered Uncovered Temperature Setting Baked Fish Uncove...

Страница 4: ...on Insulated Heater Proofer Master Switch B W G Transformer Heat Thermostat 210 F Thermo Disk M T 6 V Transformer Blower 900 Watt Heat Duct 600 Watt Red Light Power Cable Winema 5 15 Connector Electric Schematic Power Supply ...

Страница 5: ...servicio Para limpiar el gabinete limpie con un paño húmedo y seque con una toalla Utilice únicamente agentes limpiadores aprobados para aluminio No lave el gabinete con agua a alta presión No rocíe o vacíe agua en el módulo El agua que escurre al piso desde las puertas abiertas puede representar un riesgo de resbalar La responsabilidad por el uso inadecuado o descuidado es del dueño del equipo o ...

Страница 6: ...nte el gabinete hasta alcanzar la temperatura y humedad deseada el tiempo de calentamiento típico de 77 F 25 C a 95 F 35 C y 95 de humedad relativa es aproximadamente 30 minutos F Ajuste las configuraciones para alcanzar los niveles de temperatura y humedad deseados Termostato de Calor El rango de control es de 80 F a 185 F Los números en el disco 1 a 9 no se relacionan con una temperatura específ...

Страница 7: ...ables harán corto con el metal causando daño permanente Tanto el elemento como el interruptor principal con los cables del interruptor deberán ser reemplazados 6 Si la temperatura del termómetro LED no está leyendo una temperatura constante debe ser reemplazado junto con el transformador de suministro de energía Tabla de Lineamientos de Temperatura Recomendada Producto Alimenticio F Cubierto Descu...

Страница 8: ...B W G Transformer Heat Thermostat 210 F Thermo Disk M T 6 V Transformer Blower 900 Watt Heat Duct 600 Watt Red Light Power Cable Winema 5 15 Connector Interruptor máster Transformador 6V Transformador Ducto de calor Termo Disco 210F Termostato de calor Soplador Luz roja Conector del cable de electricidad Winema 5 15 ...

Страница 9: ...ou l entretien Pour nettoyer l armoire essuyer avec un chiffon humide et sécher avec une serviette Utilisez uniquement des agents de nettoyage approuvés pour l aluminium Ne pas laver le cabinet avec un jet d eau ou de l eau sous pression Ne pas vaporiser ou verser de l eau dans le module L eau qui s égoutte sur le sol alors que les portes sont ouvertes peut être un risque de chute La responsabilit...

Страница 10: ...ouhaitée Temps de chauffage typique de 77 F 25 C à 95 F 35 C et 95 d humidité relative est approximativement de 30 minutes F Régler des paramètres d atteindre les niveaux de température et d humidité désirée Thermostat de chaleur La gamme de contrôle est de 80 F à 185 F Les numéros du cadran 1 à 9 ne sont pas liés à un thermomètre étalonné Les réglages de température doivent être obtenus par le fa...

Страница 11: ...es de montage les fils se court circuiteront sur le métal causant des dommages permanents L élément et l interrupteur d alimentation principal avec des fils sur l interrupteur doivent être remplacés 6 Si la température sur le thermomètre LED n affiche pas une lecture de la température constante il doit être remplacé en même temps que le transformateur d alimentation Tableau des lignes directrices ...

Страница 12: ...former Heat Thermostat 210 F Thermo Disk M T 6 V Transformer Blower 900 Watt Heat Duct 600 Watt Red Light Power Cable Winema 5 15 Connector Commutateur principal Transformateur Transformateur 6V Conduit de chaleur 210F Disque thermal Thermostat de chaleur Surpresseur Lumière rouge Connecteur du câble d alimentation 5 15 Winema ...