Unity Low Voltage  

Disconnect & Monitor

Installation/Operation Manual

Model: ULM-100

Table of Contents

Page Table of Contents

Page

1.0 Overview

2

5.14 LVD Level Mapping

4

2.0 Materials Provided

2

5.2 Meter

4

3.0 Mounting

2

5.21 Voltage Monitoring

4

3.1 Rack Ears

2

5.23 Backlighting Adjustment

4

4.0 Wiring

2

5.24 Temperature Monitoring

4

4.1 Rectifier Input

2

5.25 Meter Power Source Selector

4

4.2 Battery Input

2

5.26 Restore to Factory Settings

5

4.3 Load Output

2

5.3 Battery Circuit Breaker

5

4.4 Alarms

3

5.4 Alarm LED

5

5.0 Operation & Adjustments

3

6.0 Connecting Rectifier Types

5

5.1 Low Voltage Disconnect

3

6.1 Unity Rectifier Shelf (URS)

5

5.1 Manual/Auto Selector Switch

4

6.2 Power Modules (PM Series)

5

5.12 LVD Adjustment

4

7.0 Troubleshooting

6

5.13 LVD Alarms: Pre-Disconnect & Disconnect

4

8.0 Specifications

6

9.0 Outline & Mounting Drawing

7

M-ULM100

030315

Содержание ULM-100

Страница 1: ...3 Backlighting Adjustment 4 4 0 Wiring 2 5 24 Temperature Monitoring 4 4 1 Rectifier Input 2 5 25 Meter Power Source Selector 4 4 2 Battery Input 2 5 26 Restore to Factory Settings 5 4 3 Load Output 2...

Страница 2: ...Head bolt for rectifier battery input load connection 10 split lock washer one per 1 4 20 Hex Head bolt above 1 Installation Operation Manual 3 0 Mounting 3 1 Rack Ears One pair of rack ears for 19 ra...

Страница 3: ...a the Molex six conductor alarm wire pigtail included with the ULM 100 See section 5 12 5 13 for information on setting Pre disconnect and LVD activation thresholds 5 0 Operation Adjustments Figure 3...

Страница 4: ...el at which the battery will be re connected after a dis connect event when AC power is restored Pre LVD Alarm Level at which the pre LVD alarm contact triggers as an early warning for a low battery d...

Страница 5: ...6 0 Connecting Rectifier Types The ULM 100 will accept any filtered rectifier input s providing total rectifier amperage does not exceed 100 Amps See Figure 5 and 6 for wiring examples of Newmar Unity...

Страница 6: ...o factory settings to aid in troubleshooting see 5 26 and the menu diagram for details 8 0 Specifications Electrical Nominal System Voltage 12 24 or 48 VDC Voltage Range 8 to 65 vdc Grounding Positive...

Страница 7: ...P O Box 1306 Newport Beach California 92663 Phone 714 751 0488 Fax 714 957 1621 E Mail techservice newmarpower com www newmartelecom com 7 9 0 Outline Mounting Dimensions...

Отзывы: