background image

 

2012 

Newmar Corporation 

October 2011

 

 

SilverLeaf RV-C Control System 

Training Manual 

Содержание SilverLeaf RV-C Control System

Страница 1: ...2012 Newmar Corporation October 2011 SilverLeaf RV C Control System Training Manual ...

Страница 2: ......

Страница 3: ...y qualified individuals Changing these control settings to an improper setting can adversely affect the operation of the control system and may cause damage to the coach The following is a list of the control and system status screens available on the Newmar SilverLeaf Control System Touch Screen Display SYSTEM SPLASH SCREEN The Splash Screen is displayed momentarily on system power up This screen...

Страница 4: ...Screen see DC Power Screen Genset Button Pressing this button selects the Genset Screen see Genset Screen Water Button Pressing this button selects the Water Control Screen see Water Control Screen Climate Button Pressing this button selects the Climate Control Screens see Climate Control Screen Temp Button Standard Control Pressing the Temp Button selects a screen that displays the outside ambien...

Страница 5: ...relay on off The button indicator is highlighted yellow when the load is being shed and blue when on STATUS DISPLAYS Overall System Status OK if no errors or warnings are present Warnings and Errors will be displayed in this area in order of priority Date Outside Temperature Time The system date outside temperature and time are displayed in this area Tank Status The Fresh and Holding tanks status ...

Страница 6: ... screen The Inverter can also be turned on and off from this screen via the blank button to the right of the Inverter Status display AC POWER SCREENS LOAD SHED MANAGEMENT SCREEN The Load Management Screen displays the Shore Power Phase setting Single Phase 30 Amps and less Service Dual Phase 50 Amp Service and allows you to change between the phase selections using the Change Button The current Am...

Страница 7: ...ge This setting sets the Load Shedding Amperage value for the Dual Phase selection This should normally be set 50 Amps AC POWER SCREENS LOAD SETTING SCREEN 2 The second Load Setting screen configures the following settings Capacity Dual Phase Amperage This setting sets the Load Shedding Amperage value for the Dual Phase selection This should normally be set 50 Amps Load Shedding Enabled Disabled L...

Страница 8: ... first Magnum Setting screen configures the following settings Inverter Status On Off Standby Charger Status On Off Standby Max Charging Current Amperage This is the maximum amount of current the charger can output Load Sense Power Wattage This is the Power Level Search Watts Setting required to activate wake up the inverter DC POWER SCREENS MAGNUM SETTINGS SCREEN 2 The second Magnum Setting scree...

Страница 9: ...ed system configuration screens The advanced configuration screens contain control settings that should only be changed by qualified individuals Changing these control settings to an improper setting can adversely affect the operation of the control system and may cause damage to the coach DC POWER SCREENS MAGNUM ADVANCED SETTINGS SCREEN 1 The Magnum Advanced Settings Screen has the following Conf...

Страница 10: ...orption Time Hr This is the amount of time that the charger will stay in Absorption Mode Float Volts DC Voltage This is the DC Voltage that will be output when the charger is in Float Mode GENSET SCREEN The Genset Screen displays the current Generator Status and control system run time Note The system generator run time can be set to match the physical generator hour meter using the OnmiScope Serv...

Страница 11: ...This screen also displays tank related faults if any The Water Pump Button turns the Water Pump on and off The Auto Fill Button turns the Auto Fill function on and off WATER SCREEN LP EQUIPPED COACH The Water Screen for a coach equipped with an LP tank displays and controls the same functions as the All Electric Water Screen with the addition of the LP tank full status ...

Страница 12: ...layed when the functions are active The Oasis control screen is only accessed from this screen The Leave function is also accessed from this screen The Leave function allows you to set different temperature set points to control the HVAC system when you leave the coach CLIMATE LVRM SCREEN The Climate LvRm Screen displays the Heating and Cooling controls for Living Room zone The Air Conditioner for...

Страница 13: ...Heating and Cooling controls for Bedroom zone The Air Conditioner for cooling and both the Heat Pump and Oasis heating systems for the Bedroom are controlled from this page CLIMATE OASIS SCREEN The Oasis Screen is accessed from the Oasis Button displayed in the Climate All Screen This screen controls the Oasis Burner and both AC Heating Elements The Burner AC 1 and AC 2 Buttons will highlight when...

Страница 14: ...The Floor Screen is accessed from the Floor Button located on the Main Screen This screen controls the Floor Heat Zones by means of the slider bars or the up and down arrows and is only available on systems with the Floor Heat option The higher the number the longer the time interval the heat mats are energized This screen also contains icons that show the heating mat status When the icon is red t...

Страница 15: ...FEATURES SCREENS SCREEN 2 Screen 2 allows access to the following features View AC Power History Button Accesses the AC Power History Screen Auto Fill Configuration Button Accesses the Auto Fill Configuration Screens Warnings Configuration Button Accesses the Warnings Configuration Screens Tank Calibration Button Accesses the Tank Calibration Screens FEATURES SCREENS SCREEN 3 Screen 3 allows acces...

Страница 16: ... Accesses the Auto Fill Configuration Screens Floor Heat Configuration Button Accesses the Floor Heat Configuration Screen Warnings Configuration Button Accesses the Warnings Configuration Screens FEATURES FLOOR HEAT OPTION SCREEN 3 Floor Heat Option Screen 3 allows access to the following features Tank Calibration Button Accesses the Tank Calibration Screens Climate Configuration Button Accesses ...

Страница 17: ...s to the following features Climate Configuration Button Accesses the Climate Configuration Screens TM102 Configuration Button Accesses the TM102 Configuration Screen Component Versions Button Accesses the Component Versions Screen View Splash Screen Button Accesses the Splash Screen ...

Страница 18: ...contains a Back Button that returns you to the previous page as well as an up down arrow that allows you to toggle the alarm between the Off Once Only or Every Day settings and a Set Clock Button The Set Clock Button takes you to Monitor Configuration page 1 which allows you to set the system time Pressing the Timer Button on the Clock Screen accesses the Countdown Timer screen This screen has two...

Страница 19: ...ems Diagnostics Screen is accessed by pressing the Next Button located on the first Systems Diagnostics Screen or from the Prev Button located on third Systems Diagnostics Screen This Screen displays communications status present on the control system FEATURES SYSTEM DIAGNOSTICS SCREEN 3 The third Systems Diagnostics Screen is accessed by pressing the Next Button located on the second Systems Diag...

Страница 20: ... Screen is accessed by pressing the Next Button located on the first Monitor Configuration Screen or from the Prev Button located on third Monitor Configuration Screen This Screen allows you to set the Day Time Display Setting by pressing the associated Up and Down Buttons FEATURES MONITOR CONFIGURATION SCREEN 3 The third Monitor Configuration Screen is accessed by pressing the Next Button located...

Страница 21: ...word Access Screen is to provide access to advanced system configuration screens These screens contain control settings that should only be changed by qualified individuals FEATURES MONITOR CONFIGURATION SCREEN 5 The fifth Monitor Configuration Screen is accessed by pressing the Next Button located on the fourth Monitor Configuration Screen or from the Prev Button located on sixth Monitor Configur...

Страница 22: ...led Select using the Up Down Arrows Floor Heat Schedule None 2 Time Zone or 4 Time Zone Select Appropriate Setting using the Up Down Arrows FEATURES MONITOR CONFIGURATION SCREEN 7 The seventh Monitor Configuration Screen is accessed by pressing the Next Button located on the sixth Monitor Configuration Screen or from the Prev Button located on eighth Monitor Configuration Screen This Screen allows...

Страница 23: ...TURES MONITOR CONFIGURATION SCREEN 9 The ninth Monitor Configuration Screen is accessed by pressing the Next Button located on the seventh Monitor Configuration Screen This Screen allows you to reset the display to the default settings or to restart reboot the display Pressing the Reset to Defaults Button will set the display to the Factory Default settings Resetting the display to the Factory Def...

Страница 24: ...ally starts and stops the generator based on the Auto Charger Configuration Settings Battery Voltage Max Run Time Top Off Voltage and Top Off Run Time Please note that the generator will not automatically start if Shore Power is present Press the associated button to change the setting Exerciser Enabled Disabled When Enabled this function will automatically run the generator based on the Exerciser...

Страница 25: ...wn Arrows Topoff Run Time min Time Set This setting determines the amount of time before Quiet Time begins to automatically start the generator if the Auto Charger function is Enabled and the house battery voltage is below the Topoff Volts setting If these conditions are met the generator will automatically start and run until Quiet Time begins Select value using the Up Down Arrows FEATURES AUTO G...

Страница 26: ... screen is accessed by pressing the Next Button located on the fourth Autogen Configuration screen This screen allows you to change the following settings Auto Temp Set Point Temperature Set Point The Auto Temp Set Point determines the temperature setting to automatically start the generator when the Zone 2 temperature rises above the set point for the time value set by the Auto Temp Delay Time Th...

Страница 27: ...r the tank full function If the Auto Fill function is Active and the Fresh tank level rises above this value for the Run After time setting the fill valve will close to stop filling the tank Select value using the Up Down Arrows Max Time Out Numeric min Time Value If the Auto Fill Function is Enabled and the Fresh Tank is not filling this setting controls the amount of time the Fill Valve will be ...

Страница 28: ...Stop Level or the tank will over flow Select using the Up Down Arrows FEATURES FLOOR HEAT CONFIGURATION SCREENS FLOOR HEAT with No Time Schedule Screen The Floor Heat Configuration Screen is accessed by pressing the Floor Heat Configuration Button located on the Features Configuration Screen This screen is only applies to systems with the Floor Heat option These selections set the floor heat zone ...

Страница 29: ...Time Setting Select using the Up Down Arrows Day Setting Floor Heat Setting Select using the Up Down Arrows Night Setting Floor Heat Setting Select using the Up Down Arrow FLOOR HEAT with 2 Time Schedule Screen 2 of 2 The Floor Heat Configuration Screen is accessed by pressing the Floor Heat Configuration Button located on the Features Configuration Screen This screen is only applies to systems wi...

Страница 30: ...Setting Select using the Up Down Arrows AM On Setting Floor Heat Setting Select using the Up Down Arrows FLOOR HEAT with 4 Time Schedule Screen 2 of 3 The Floor Heat Configuration Screen is accessed by pressing the Floor Heat Configuration Button located on the Features Configuration Screen This screen is only applies to systems with the Floor Heat option These selections set the 2 time zones floo...

Страница 31: ...et the floor heat zone names displayed on the Floor Screen Depending on the HMS360 Touch Screen Display Software Version this screen or a similar screen may be located under the Climate Configuration Screens not under the Floor Heat Configuration Screens This screen allows you to change the following settings Floor 1 Name Set to Front Select using the Up Down Arrows Floor 2 Name Set to Mid Select ...

Страница 32: ...this value Select value using the Up Down Arrows Black Tank Warning Numeric Percentage Value A warning message will be displayed if the Black tank level drops below this value Select value using the Up Down Arrows Battery Warning Numeric DC Voltage Value A warning message will be displayed if the House Battery Voltage level drops below this value Select value using the Up Down Arrows FEATURES WARN...

Страница 33: ...figuration Screen and entering the correct password or by pressing the Prev Button located on the second Tank Cal screen This screen sets the tank capacities for the coach with the following settings Fresh Tank Size Essex 105 Gal King Aire 140 Gal Select value using the Up Down Arrows Gray Tank Size Essex 65 Gal King Aire 80 Gal Select value using the Up Down Arrows Black Tank Size Essex 45 Gal Ki...

Страница 34: ...e set with tank empty or the sensor removed and exposed to atmospheric pressure This screen controls the following functions Pressing the Fresh Dry Calibrate Button sets the Fresh Tank Sensor Dry Point Pressing the Gray Dry Calibrate Button sets the Gray Tank Sensor Dry Point Pressing the Black Dry Calibrate Button sets the Black Tank Sensor Dry Point This screen allows you to confirm or cancel se...

Страница 35: ...cess to advanced system configuration screens The advanced configuration screens contain control settings that should only be changed by qualified individuals Scheduling This feature allows you to set different HVAC set points depending on the time of day Select value using the Up Down Arrows Sec Heat Mgmt Set to Automatic This setting determines how the Oasis Heating System is controlled Select v...

Страница 36: ...wn Arrow on the third Climate Setting screen or by the Left Up Arrow on the sixth Climate Setting screen This screen sets the Cool Source to the HVAC Zones Cool Instance 1 Set to 1 Select using the Up Down Arrows Cool Instance 2 Set to 2 Select using the Up Down Arrows Cool Instance 3 Set to 0 Select using the Up Down Arrows Cool Instance 4 Set to 4 Select using the Up Down Arrows FEATURES CLIMATE...

Страница 37: ...een or by the Left Up Arrow on the ninth Climate Setting screen This screen specifies the Oasis Zones to control from the HVAC Zone settings Sec Heat Instance 1 Set to 164 Select using the Up Down Arrows Sec Heat Instance 2 Set to 0 Select using the Up Down Arrows Sec Heat Instance 3 Set to 166 Select using the Up Down Arrows Sec Heat Instance 4 Set to 167 Select using the Up Down Arrows FEATURES ...

Страница 38: ... Features Configuration Screen This screen displays the active system functions FEATURES COMPONENT VERSIONS SCREEN The Component Versions screen is accessed by pressing the Components Versions Button located on the Features Configuration Screen This screen displays all of the RV C Modules and their firmware versions found on the system ...

Страница 39: ...1 Instance 1 Zone Temp Display Source Zone 1 Temp Instance 1 Zone 1 Secondary Heat Instance 164 Zone 2 Temp Instance 2 Zone 1 Compressor Instance 2 Zone 3 Temp Instance 248 Zone 1 Fan Instance 3 Zone 4 Temp Instance 4 Zone 2 Instance 2 Primary Source 3 Heat Pumps Zone 1 Furnace Instance 1 Zone 2 Secondary Heat Instance 165 Zone 2 Furnace Instance 2 Zone 2 Compressor Instance 4 Zone 3 Furnace Insta...

Страница 40: ...nstance 3 3 Target Instance 4 4 Target Instance 5 0 Thermostat Instance 1 164 Thermostat Instance 2 0 Thermostat Instance 3 166 Thermostat Instance 4 167 Thermostat Instance 5 0 Echo Instance 1 1 Echo Instance 2 0 Echo Instance 3 248 Echo Instance 4 4 Echo Instance 5 0 AC1 Load Instance 0 AC2 Load Instance 0 AC1 Load Amp 0 AC2 Load Amp 0 Auto Engine Heat 0 AC1 Shed Monitor 11 AC2 Shed Monitor 12 ...

Страница 41: ...Page 39 ALL ELECTRIC OPTION LP STANDARD ...

Страница 42: ...Page 40 All Electric Option LPG Tank Set to Off LP Standard LPG Tank Set to On ALL ELECTRIC OPTION LP STANDARD ...

Страница 43: ...Page 41 ...

Страница 44: ...Page 42 ...

Страница 45: ...Page 43 EXDP TANK CAPACITIES KGDB TANK CAPACITIES ...

Страница 46: ...Page 44 ...

Страница 47: ...Page 45 ...

Страница 48: ...Page 46 ...

Страница 49: ...Page 47 ...

Страница 50: ...Page 48 ...

Страница 51: ...Page 49 ...

Страница 52: ...Page 50 ...

Страница 53: ...Page 51 ...

Страница 54: ...Page 52 ...

Страница 55: ...Page 53 ...

Страница 56: ...Page 54 ...

Страница 57: ...Page 55 ...

Страница 58: ...Page 56 ...

Страница 59: ...Page 57 ...

Страница 60: ...Page 58 Blank Page ...

Страница 61: ...nector on each end with one or more drop mini fit jr connectors along the adjacent edge The beginning and end of the entire Trunk has a Terminating Resistor built into the last Drop Tee Board The terminating resistors are required to assure proper communications across the network The control nodes are interfaced to the network using Drop cables similar in construction to the Trunk cables The stan...

Страница 62: ... Temperature Sensor Bathroom Zone 3 Temperature Sensor and Block Heater Relay SPX 300 External Display Water Works Compartment Holding Tanks Fill Status Water Pump and Auto Fill Control HMS 360 Touch Screen Display Front Overhead System Monitor and Control HMS 360 Touch Screen Display Bedroom Overhead System Monitor and Control Standard on King Aire Optional on Essex TM 502 Magnum Master DS 4 Comp...

Страница 63: ...till missing or incorrect then verify that the Monitor Configuration and any related button function Configurations are correct HVAC System Malfunction The HVAC System is controlled by three different RV C Nodes depending on the particular function The TM 510 Dometic Module controls the three roof Heat Pump Air Conditioners Zones the OA 600 Oasis Module controls the Living Room Bathroom and Bedroo...

Страница 64: ... not Light 1 Verify that the Oasis button is highlighted If not then press the Oasis button 2 If the Burner still does not light then plug in the Oasis Remote Control in place of the SilverLeaf Control and set the Burner Switch to on If the Burner still does not light then the problem lies in the Oasis system If the Oasis Burner will not stay On 1 Verify that the Oasis button is highlighted If not...

Страница 65: ...nd verify that the pump no longer turns off during the Auto Fill cycle If the Water Pump will not Turn On 1 Verify that the Water Pump button is highlighted Blue If not then press the Water Pump button 2 If the button is highlighted then verify that the Water Pump Relay 3 on the 12V Relay Interface Board is energized If the relay is on then the associated LED 3 located on the bottom of the board w...

Страница 66: ...City Supply Pressure Switch is supplying DC voltage to the TM102 Input 10 8 If the pressure switch is not supplying DC voltage then verify that voltage is being supplied to the switch If voltage is available to the switch then verify that City Supply pressure is present at the switch 9 If City Supply pressure is not available at the switch then check that the switch is plumbed correctly Correct an...

Страница 67: ... Screen then verify that the remote switch Dash etc wiring is correct and that the switch is supplying a ground signal to the TM 102 Input 2 Correct any generator wiring issues and retest the Generator remote start stop functions 4 If the Generator will not start from the Touch Screen and you have completed the previous test then verify the TM 102 configuration Correct the configuration as require...

Отзывы: