50
Troubleshooting the stove
Problem
Probable Cause
Action
The rapid build up of creosote in
the chimney
Wet wood
(Over 20% moisture content)
Use dry seasoned hardwood (less
than 20% moisture content).
To avoid a large buildup of creosote
operate the stove at a higher
temperature for a short period of
time whenever the stove is used.
Warning
: Do not exceed the
maximum fuel load stated
Flue joints expelling tar
Stove operated at a continuous low
temperature
Operate the stove at a higher
temperature for a short period of
time whenever the stove is used.
Warning
: Do not exceed the
maximum fuel load stated.
Refer to user instructions
Poor quality wood being used
Use dry seasoned hardwood (less
than 20% moisture content)
When the stove is lit a strong smell
occurs
Stove operated at a continuous low
temperature
Operate the stove at a higher
temperature for a short period of
time whenever the stove is used.
Warning
: Do not exceed the
maximum fuel load stated.
Refer to user instructions
Poor quality wood being used
Use dry seasoned hardwood (less
than 20% moisture content)
Noisy air control (wind noise)
Flue draught high
Consult your stove installer
Excessive dirty glass
Wet wood
(Over 20% moisture content)
Use dry seasoned hardwood (less
than 20% moisture content)