Enter Setup
35 *
* Exit Setup
Image Stabilization Timeout
This parameter defines the amount of time that the scanner waits for the image to stabilize to a point that
it can be decoded with more accuracy. It is programmable in 1ms increments from 0ms to 1,600ms. The
default setting is 500ms. To learn how to program this parameter, see
Appendix 5
.
Continue after Good Read
Continue after Good Read:
The scanner starts next decode session after a good read.
Pause after Good Read:
The scanner starts another round of illumination monitoring and image
stabilization after a good read.
Timeout between Decodes
This parameter sets the timeout between decode sessions. When a decode session ends, next session
will not happen until the timeout between decodes expires. It is programmable in 1ms increments from 0ms
to 65,535ms. The default setting is 1,000ms. To learn how to program this parameter, see
Appendix 5
.
Timeout between Decodes
Image Stabilization Timeout
** Pause after Good Read
Continue after Good Read