Start Setup
】
【
Exit Setup
】
71
CodeID Setup
To activate the set
up function by reading “CodeID setup”, then read the hexadcimal value inaccordance with the character
which will be set to the CodeID.
Code ID Setup
Example: Set the CodeID ofCode 93
to “p” (the hexadcimal value is 0x70).
1.
Read the “Start Setup” barcode.
2.
Read the “CodeID Setup” barcode.
3.
Read the numeric barcode “7”, “0” (see the appendix—numeric barcode)
4.
Read the “Save” barcode.(see the appendix—numeric barcode)
5.
Read the “Exit Setup” barcode.
Check Setup
Code 93 barcode data does not compulsively include the check digit, if check digit exists, then it is the last character.
Check digit is calculated according to all the datas, for checking if the data is correct or not.
Set “No Check”, the scanner will transmit all the barcode data
Set “Check but do not Send Check digit”, the scanner will check according to the last bit, if successful, all the data
except for the check digit will be transmitted, if failed, then the scanner will indicate “barcode reading failed”
Set “Check and Send Check digit” the scanner will check according to the last bit, if successful, all the data including
the check digit will be transmitted, the check digit will be treated as the last bit of the normal data; if failed, then the
scanner will indicate “barcode reading failed”
No Check
Check and Send Check Digit
Check but do not Send Check Digit
Note: by setting “do not send the check digit”, if the data length except for the 1 character check digit is less than the
minimum barcode reading limit, the barcode reading will be failed. (For example: the scanner set the the minimum
barcode reading leng
th of Code 93 to 4 characters and “do not send check digit”, in such circumstances,the scanner is not
Содержание NLS-HR15XX-30
Страница 1: ...NLS HR15Series NLS HR15XX 30 Corded 1D Barcode Scanner User Guide ...
Страница 9: ...Save and Abort the Setup 94 ...
Страница 10: ......
Страница 18: ...8 Reading Depth of Field ...
Страница 25: ... Start Setup Exit Setup 15 SetupProcess Flow ...
Страница 37: ... Start Setup Exit Setup 27 USB Virtual Serial Port Function USB Virtual Serial Port Function ...