Error Messages Cont’d: 

 

Er8  

Bad (Open) Motor Driver - The 
motor errors (Er7 and Er8) do 
not cause a system error and 
will not shut down the machine. 
Immediately upon detection the 
machine will beep twice and 
show the error message. Every 
time the key is pressed to 
activate the auger motor it 
clears the error and allows 
another attempt to be made. If 
this error occurs the dump 
valve still will release water. 

Bad/open motor driver. Product 
Auger 

Retry auger if the error still 
occurs then replace main 
board.  

Erb  

Dry Firing Tank – the tank is 
empty but the heater is on.  

The control board has either seen 
a rise in temperature of 1 degree 
a second, for 5 seconds or has 
seen the temperature rise to 
215

°

F or above 

The unit has been in the 
intent to brew timeout for an 
extended period of time, 
allowing the tank to evaporate 
to the point where there is 
little water in the tank 

ErC 

Thermistor Error 

Resistance extremely high from 
upper or lower thermistor will 
cause or the resistance extremely 
low from upper or lower 
thermistor will cause a tHU or tHL 
warning for the thermistor that 
sees the condition and causes 
the control board to switch from 
watching the lower to the upper 
thermistor. If both the upper and 
lower resisters fail then we flag a 
thermistor error 

Check/replace thermistor. 

 

Note: Turn machine Off then back On to Clear Error Messages

 

 
 
 
 
 
 
 
 
 
 
 

Содержание Bistro 1

Страница 1: ...BISTRO 1 By NEWCO Enterprises Installation And Programming Guide...

Страница 2: ...t to o a al ll l o of f o ou ur r b br re ew wi in ng g e eq qu ui ip pm me en nt t Turn water Supply On Plug or wire brewer to the appropriate voltage circuit as indicated on the serial tag Locate po...

Страница 3: ...3 switch control panel w lighted display screen Three dashed lines will appear on the display screen as shown in figure 1 Step 1 Enter a Programming Mode Press and hold the center switch labeled Enter...

Страница 4: ...h to save and proceed to the next programming option Either the word YES or the word NO will appear on the display screen Proceed to Step 3 Step 3 Beeper Selection ON or OFF On or will appear on the d...

Страница 5: ...ed to deliver different strength drinks or different sized drinks See Programming directions on page 6 Changing the Gram Throw Auger Speed To change the AUGER SPEED for the Augers using the selector s...

Страница 6: ...e switch labeled Single Shot The display will change to identify the switch that you have chosen as in Fig 6 2 2 Press Enter The number 1 and the current auger speed will appear in the display as show...

Страница 7: ...us flow push and hold mode the time value will be 0 00 Shown in figure 9 5 Press and release the settings button to store switch settings The display will return to SEL To program another switch repea...

Страница 8: ...out period Timeout period is 120 seconds which is reloaded whenever the heater is off or the fill valve is on Check element for short and proper resistance Check heater relay Check for tripped button...

Страница 9: ...empty but the heater is on The control board has either seen a rise in temperature of 1 degree a second for 5 seconds or has seen the temperature rise to 215 F or above The unit has been in the inten...

Страница 10: ...1 NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 12 09 10 10 Dimensions Electrical Specifications Electrical Specs Bistro 1 Machine 120V 1600W 15 Amps IDQ HOT CHOCOLATE DISPENSER 18 07 21 3...

Страница 11: ...TO ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The agents dealers or employees of NEWCO are not authorized to make modifications to this warranty or to make addi...

Страница 12: ...Bistro 1 NEWCO Enterprises Phone 1 800 325 7867 Fax 1 636 925 0029 12 09 10 12 Wiring diagram...

Отзывы: