Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 5 -
Step 4. Program Selector Switches
This machine features a 6-selector switch control panel.
These 6 switches can be programmed to deliver different
strength drinks or different sized drinks-
See Programming
directions on page 6.
Changing the Gram Throw (Auger Speed):
To change the AUGER SPEED for the Augers using the
selector switch (Figure 9)
Gram Throw Speed (1-25)
Approx.
Gram Throw
Auger Speed
Setting
9 g/oz
11
8 g/oz
10
7 g /oz
9
6 g /oz
8
5 g /oz
7
4 g /oz
6
3 g /oz
5
THIS TABLE IS FOR REFERENCE, SET FINAL AUGER SPEED BY TASTE