background image

6

you  are  still  unsure  whether  the 

kegerator

  has  been  properly  installed,  we 

recommend that you contact a qualified installer.

Ÿ

Note: Allow the 

kegerator 

to stand in an upright position for at least 8 hours 

before plugging in the unit. This is very important! Once the unit is laid on its side, 
the  refrigera

nt

in  the  refrigeration  system  is  shifted.  The  refrigerant  in  the 

refrigeration system needs to stabilize before the unit is turned on.

Installing the Casters

Follow the steps below to install the casters.

Empty the inside of the cabinet completely and lay the 

kegerator

 down on its side. 

We recommend that you place a piece of cardboard or cloth underneath 
the cabinet to prevent dents or scratches.

1.

Note:  Two  of  the  casters  include  locking 
mechanisms  to  ensure  the  unit  does  not 
slide  on  hard  floors.  These  two  locking 
casters  should  be  fastened  at  the  front 
end of the unit, with the unlocked casters 
fastened on the rear end.

2.

3.

Insert  the  casters  into  the  holes  on  the  bottom  corners  of  the  cabinet.  Tighten 
each  caster  by  turning  the  head  of  the  bolts  clockwise  with  a  wrench.  (

N

ot 

provided in the kit

.

)

Once  all  four  casters  have  been 
tightened,  stand  the  cabinet  in  its 
upright position.

Installing the Beer Tap

Follow the steps below to install the beer tap.

There are notches on the bottom of the draft arm 
assembly  that  line  up  with  grooves  inside  the 
opening on the top of the kegerator. Align 

simply lock it into place.U

s11 &12 

)

Beer

Dispenser

  Tower

Beer Duct

Guard Rail

ASSEMBLY INSTRUCTIONS

the draft 

arm with the opening on the top of the  unit, then 

place  inside  and  twist  until  secure.  No screws are

  black  gasket  for assembly. (See Illustrations C & 

D on page

)

necessary, 

 

se  the  thin

Содержание AK-200 SERIES

Страница 1: ...Please read and save these instructions AK 200BK KEGERATOR OWNER S MANUAL AK 200 SERIES ...

Страница 2: ...the CO Regulator and the CO Cylinder 2 2 Tapping the Beer Keg Installing Keg Tap ASSEMBLY INSTRUCTIONS SAFETY PRECAUTIONS Important Safety Precautions of CO2 Proper Location Use of Extension Cords Carbon Dioxide Gas Cleaning Maintenance Storage care OPERATING YOUR KEGGER MEISTER SPECIAL SAFETY INFORMATION SPECIAL SAFETY INFORMATION Quick Assembly Instructions QUICK ASSEMBLY INSTRUCTIONS Limited Ma...

Страница 3: ...on cords or adapters to connect the unit to an electrical power source Unplug your appliance before cleaning or making any repairs We suggest that a certified technician perform the service if for any reason this product requires service If your old appliance is being discarded we recommend that you remove the door and leave the shelves in place This will reduce the possibility of danger to childr...

Страница 4: ...thout supervision This appliance is NOT A TOY Young children should be supervised to ensure that they do not play with this appliance When transporting the refrigerator keep the unit in the upright position Do not tilt the appliance beyond 45 or place the unit in an upside down position 21 22 23 24 ...

Страница 5: ... a CO cylinder 2 Always keep CO cylinders away from heat Store extra cylinders at a cool 2 place preferably lower than 70 F Securely fasten with a chain in an upright position when storing Always ventilate and leave the area immediately if CO leakage has occurred 2 There are two safety devices in the pressure system in the form of a valve One safety feature is on the CO bottle The second is on the...

Страница 6: ...ght This kegerator is designed for indoor use only it should not be used outdoors This kegerator is a freestanding design and should not be placed in a built in or recessed area Kegerator unit dimensions 21 3 W x 33 20 H with casters x 26 60 D The following dimensions are recommended for clearances around the kegerator Sides 5 12 cm Back 5 12 cm DANGER Use of Extension Cords Always avoid using an ...

Страница 7: ... mechanisms to ensure the unit does not slide on hard floors These two locking casters should be fastened at the front end of the unit with the unlocked casters fastened on the rear end 2 3 Insert the casters into the holes on the bottom corners of the cabinet Tighten each caster by turning the head of the bolts clockwise with a wrench Not provided in the kit Once all four casters have been tighte...

Страница 8: ...ust also have your CO cylinder filled at your local 2 supplier See page 4 item 9 for suggested locations within your community Install the CO gas line tube to the regulator by attaching one end of the tube to the hose barb connection on the CO regulator See Illustration B on page 6 Insert the special washer provided with the kit into the regulator to cylinder attachment nut See Illustration A on p...

Страница 9: ...er Tighten it firmly by hand Fig 2 below Attach the CO line end of the tube to the hose connection on the tap Next secure the tube by using the remaining self locking plastic snap on clamp to ensure that there are no leaks Secure the clamp tightly with pliers Fig 3 below Make sure the beer tower faucet is in the closed handle pointing straight back position before connecting the tap to the keg To ...

Страница 10: ...gged in properly to a 120V 60Hz 15Amps grounded AC power outlet Place the drip tray under the beer faucet to avoid messes from excess beer Open the beer faucet by pulling the tap towards you to dispense the beer Note If for any reason the beer does not come out of the tap please refer to the Tapping the Beer Keg Installing Keg Tap section Increase the pressure if the beer runs too slowly Hold the ...

Страница 11: ...hat is trapped inside helping to prevent any bacteria or mold that could accumulate inside In order to clean and remove any excess beer that may leak into the unit space inside the door remove the black rubber insulation and wipe with a wet towel as needed 1 2 3 4 Detach beer line Flush hose with water Storage Care Follow the guidelines below to care for your kegerator when not in use Please adjus...

Страница 12: ...gulator and tapping device so that they cannot be removed or by 2 passed Illustration C 11 SPECIAL SAFETY INFORMATION Your kegerator system has two safety devices already provided in the CO2 run either one of these 5 gallon kegs you may need to obtain an alternate keg connector the 5 gallon Cornelius Keg and the 5 gallon D System Keg should you decide to sized barrel and the Barrel full size US Ke...

Страница 13: ...Illustration D Illustration E 12 SPECIAL SAFETY INFORMATION ...

Страница 14: ...up on casters and allow Freon to settle for at least 8 hours before plugging in All O rings and rubber washers are preinstalled by the factory but should be double checked The bag of O rings and rubber washers included are replacement pieces Installing Tower Illustrations on page 1 Remove cap from top of refrigerator 2 Drop beer line connected to beer tower 6 through the opening in the 13 QUICK AS...

Страница 15: ...d end first into top opening of coupler 1 Insert rubber washer 3 into wing nut at end of beer line Screw wing nut onto top opening of coupler Installing Coupler 1 Make sure black handle on coupler 1 is in the UP position 2 Insert coupler 1 into keg and turn clockwise to lock 3 Pull and hold black handle on coupler 1 up and bring lever down to lock into place Regulating Keg 1 Turn CO tank valve cou...

Страница 16: ...15 QUICK ASSEMBLY INSTRUCTIONS Band 6 ...

Страница 17: ...h as low voltage defective household wiring or inadequate fuses 4 Accident alteration misuse or abuse of the appliance such as using non 5 Use in commercial or industrial applications 6 Fire water damage theft war riot hostility or acts of God such as hurricanes floods etc 7 Use of force or damage caused by external influences 8 Partially or completely dismantled appliances Obtaining Service When ...