Configuring the MX100-TG
MX100-TG User Manual
40
may be set to 1 to enable special handling. Multiple bits can be set
to enable multiple functions on particular ISDN. The default setting
of the
Flag
parameter is
0x0000
. Various settings and their
behavior are explained in the following table.
Table4: ISDN Flag Settings
Setting
Behavior
0x0000
Default
0x0001
The MX100-TG will send SERVICE message
when ISDN layer 2 is up, and before layer 3 is
ready. Some PBXs require this message in
order to function properly
。
0x0002
Allow cut-through without called party number
(CDPN). (Normally ISDN call without a CDPN
will be rejected.)
A typical application is for large company
PBX expansion: PBX1 => MX100-TG1 => IP
=> MX100-TG1002 => PBX2.
0x0004
Enable second stage dialing. When an ISDN
call comes in, the MX100-TG will cut-through
and play dial tone while collecting digits for
further routing.
This is used in calling card or PSTN-VoIP
number bonding applications.
0x0008
This setting is used in conjunction with
second stage dialing (0x0004) and plays an
announcement instead of dial-tone for digit
collection. The MX100-TG has *.pcm files
(audio format) that can be customized and
loaded for this application. Contact Newrock
support for more details.
0x0010
This setting is used in conjunction with
second stage dialing (0x0004). If configured,
after digit collection, the MX100-TG will use
the original CPN for the CPN of the second
stage dialing of the call. (Otherwise the
original CDPN will be used as the CPN of the
second stage.)
Содержание MX100-TG
Страница 1: ...MX100 TG USER MANUAL Release 3 0 ...
Страница 7: ...MX100 TG User Manual 7 Cautions show information requiring extra attention ...
Страница 11: ...ABOUT THIS BOOK MX100 TG User Manual 11 Fax 86 21 61202704 ...
Страница 67: ...Monitoring MX100 TG User Manual 67 Figure 21 Startup Information Log ...
Страница 71: ...System Tool MX100 TG User Manual 71 Figure 25 Gateway Restart Screen ...
Страница 75: ...New Rock Technologies Inc 75 ...