Chassis and Components
MX100-TG User Manual
17
Red (on)
Alarm condition with a known
source
T1/E1 Module
The T1/E1 Module (shown in figure 3) always has four active RJ-45
connections. Pinouts are shown as follows:
RJ45
Pin-out 1
2
3
4
5 6 7 8
Description RX_Ring
RX_Tip
NC
TX_Ring
TX_Tip NC NC NC
Since the Control Module controls the capacity of the system, only
the supported number of T1/E1 lines should be connected.
Figure 3. T1/E1 Module
Do not connect T1/E1 lines in excess of the system’s
capacity.
To determine the capacity of the MX100-TG see the
product label.
Rear View
Figure 4 shows the rear view of an MX100-TG chassis.
Figure 4. MX100-TG Gateway, Rear View
Power Supplies
The MX100-TG contains two auto-ranging power supplies. They are
capable of 100-240 VAC, 47-63 Hz. The supplies are redundant and
hot-swappable. While both supplies are installed, both are running
and sharing the power load of the MX100-TG. The power light