7
5. Installation
5-1. Installation
Method
WARNING
The cable entry device and blanking elements shall be of ATEX certified in type of
explosion protection flameproof enclosure ‘’d’’, suitable for the condition of use and
correctly installed.
Use in ATEX hazardous area, ATEX certified cable glands according to EN
60079-0:2012 and EN 60079-1:2007 shall be provided by end-user.
Use in IECEx hazardous area, IECEx certified cable glands according to IEC
60079-0:2011 and IEC60079-1:2007 shall be provided by end-user.
Unused apertures shall be closed with suitable ATEX certified blanking elements.
Fastener type M5 x 16 shall have a yield stress factor of min. 450 N/mm2.
The dimensions of flameproof joint between casing and casing cover of KD-12
flameproof housing are exceeding the minimum requirements stated
EN/IEC60079-1. Please contact the manufacturer for inspection, repair and/or
adjustments of this flameproof.
Installation of cable gland and sensor:
-Casing to cable glands -Casing to sensor
Thread size : PF3/4 or G3/4
Thread size : M27
Pitch : 1.81mm
Pitch : 1.5mm
Insertion length : 10.86mm Insertion length : 8.25mm
Number of insertion threads : 6
Number of insertion : 5.5
Shall lock the sensor unit and cable gland by the stainless steel socket head screw
before use.
* Top of socket head screw shall not be over the casing surface.