6. Wiring
Method
6-1. Wiring
Work
Be sure to provide explosion-proof wiring if the product is to be used in hazardous places.
Cable Work
Use a shielded cable, such as CVV-S with a thickness of 1.25 to 2.00 mm
2
. Lay all cables in
protective tubes, such as metal conduits or carbon steel pipes, or other protective structure,
such as a concrete duct.
When using the external contact function of the product, which requires a five-conductor cable,
make sure that the maximum diameter of the cable conductor is 1.25 mm
2
. When using only
the analog signal function, which requires a three-conductor cable, without the external
contact function, make sure that the maximum diameter of the cable conductor is 2.00 mm
2
.
CAUTION
All necessary work for the product including wiring and installation should be carried out
by suitably trained personnel in accordance with applicable code of practice.
Inspection, maintenance and repair of the equipment should be carried out by suitably
trained personnel in accordance with applicable code of practice.
WARNING
The cable entry device and blanking elements shall be of ATEX certified in type of
explosion protection flameproof enclosure ‘’d’’, suitable for the condition of use and
correctly installed.
Unused apertures shall be closed with suitable ATEX certified blanking elements.