![Neve Custom Series 75 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/neve/custom-series-75/custom-series-75_owners-manual_1676771026.webp)
26
Control room
The high fidelity Control Room monitoring circuitry allows
for sonically transparent monitoring of up to 12 sources.
Located in the bottom right hand corner of the Master
Section, it hosts the Main Monitor Volume Control, source
selection for the Control Room Monitors, global Solo
Modes, and Talkback controls.
Other features include a Control Room Headphone
Output and an input labeled iMOn - This is an 1/8” TRS
input designed for monitoring of external equipment, such
as MP3 players, through the Control Room Speakers.
Control room Volume
and Controls
By far, the most exhaustive amount of effort of all of the
Series 75 features has gone into the design of the Control
Room Volume circuitry.
Up to three pairs of monitors can be connected to the
Series 75 (see Connections for details).
MaIn - Routes the selected Monitor Source to the Main
Spk outputs.
alT1 - Routes the selected Monitor Source to the Alt Spk
1 outputs.
alT2 - Routes the selected Monitor Source to the Alt Spk
2 outputs.
NOTE: ALT2 can be used as a third pair of stereo
monitors, however also supports eight outputs for 7.1
surround sound monitoring. Selecting 7.1 in the Monitor
Source section in combination with ALT2 routes the 7.1
Input to the ALT2 Speaker Outputs.
lCuT & rCuT - These cut the left and right channels
of the currently selected Speaker Outputs. If monitoring
surround using ALT2, just the L & R speakers will be cut.
MOnO - Feeds a mono sum of the selected Monitor
Source to the Speaker Outputs.
Further, if lCuT and MOnO are selected, the right
channel of the Monitor Source will be routed to the
selected left AND right Speaker Outputs. If rCuT and
MOnO are selected, the opposite occurs.
Further still, if MOnO and swaP are selected,
the left and right channels of the selected Monitor
Source are subtracted, and only the difference is
heard.
When used in conjunction, LCUT, RCUT and MONO
could be useful for calibrating speakers, checking
for mono mix compatibility, focusing on signals
present only in one channel of the selected Monitor
Source, and the list goes on…
CuT - Cuts the selected Speaker Outputs.
swaP - Reverses the selected L & R Speaker
Outputs.
DIM - Dims the Speaker Outputs by a level set by
the Dim Control. The DIM button will be activated
automatically when the following buttons in the
Talkback section are activated: auX, Cue, HP1 and
HP2.
Monitor source
The Monitor Source section of the Series 75 Control
Room panel is a 12 input analogue summing mixer, using
high fidelity modern assembly methods for transparency.
Up to 12 sources may be selected and monitored at
once.
2T1 - Routes 2 Track 1 to the selected Speaker Outputs
via the Main Volume control.
2T2 - Routes 2 Track 2 to the selected Speaker Outputs
via the Main Volume control.
7.1 - Routes the 7.1 input to the selected Speaker
Outputs via the Main Volume control. The ALT2 Speaker
Outputs are 7.1 capable.
NOTE: Selecting 7.1 also alters the Group Cuts and
Solos, which will now affect the ALT2 Speaker Outputs.
This allows the additional ability to cut or solo individual
speakers when monitoring in surround sound.
iMOn - Routes the iMON input (top left corner of the
iMON
HP + PFL
CRM
HP
PFL
Hp1
Hp2
AUX B
2T1
2T2
7.1
iMON
AUX 3
AUX A
SUM
RETRO
OP
MODERN
OP
MON
MIX
AUX 1
AUX 2
MONITOR SOURCE
LISTEN
MIC
TALKBACK
TALK
0
11
1/2
DIM
SOLO
AFL PFL SIP SIF
0
-30
CAL
SURROUND
MAIN
LCUT
CUT
ALT2
RCUT
DIM
ALT1
MONO
SWAP
SOLO
CLEAR
SOLO
MODE
LINK
HP1
HP2
AUX
CUE
LISTEN
SLS
RED
LIGHT
STATUS
LOCK
SOURCE IN MONO