Container Cleaning System TANKO®EX-R64T
8 Faults
Translation - Operating/installation instructions 2020/03
71/80
8.2
Faults and Remedial Action
Fault
Cause
Remedy
Screw connection not
tight.
Thread damaged.
Replace the device.
Thread not tightened
completely.
Retighten the threaded connection.
Effectiveness of cleaning
is not sufficient.
Connection pressure too low.
Check and increase the connection
pressure.
Attention! Do not exceed operating
pressure (see
.
Connection pressure too high,
cleaning medium turns into
mist.
Check and reduce the connection
pressure.
Distribution / cleaning
device does not turn.
Openings closed.
Clean openings.
Openings deformed.
Replace the device.
Ball bearing worn.
Replace the device.
Table 8.2-1: Operational Disruptions – Cause and Remedy
If the specified measures are NOT successful, please contact AWH.
If the device is sent back (e.g. repair/service/return), it is necessary for a hazardous substances
declaration to be enclosed with the device in compliance with the German Ordinance on
Hazardous Substances (GefStoffV).
Request the form for the hazardous substance declaration from AWH.
8.3
What to Do in an Emergency
If a hazardous situation occurs, or if you need to avert a potential danger, quickly switch the device to a
safe state.
The type of EMERGENCY STOP circuit used for the device is to be determined depending on the hazards
and operating conditions and is the sole responsibility of the owner.
It is for this reason that AWH can offer the owner, solely as a precautionary measure, a few points of
reference and notes to be observed and to be integrated into the owner's hazard assessments.
–
The work steps for switching off the device listed in
adhered to.
–
The EMERGENCY STOP circuit must be designed in such a way that the machine or system operator
can actuate it immediately in the event of an emergency.
–
Switching off in an emergency (“EMERGENCY STOP") is intended to disconnect the entire machine from
the power supply without delay in order to eliminate the risks caused by electrical voltage immediately.
–
Shutting down in an emergency ("EMERGENCY STOP”) is intended to prevent risks that cause
hazardous movements as soon as possible.
–
The EMERGENCY STOP must have priority over all other functions and actuations in all operating modes.
–
Resetting must not cause the plant/machine to start up again.