5. Firmware Updates
NetXen, Inc.
Intelligent NIC Getting Started Guide — NDA Required
21
NX Interface is eth2
Supported flash
Firmware version: 3.4.2
Bios version: 255.255.65535
MAC Addr 0 : 00:0E:1E:00:03:78
MAC Addr 1 : 00:0E:1E:00:03:79
Subsys ID : 0x11223344
5.2
Windows Firmware Update
The following steps are used for updating the Windows OS firmware.
1
Open DOS Command window.
2
Go to the
utils
directory in the driver package provided.
3
The following binaries are required to be in the same directory from where the Flash
command will be executed:
nxflash.exe
phantom_obj
bootld
4
Run the following commands:
nxflash -i NX_NIC -u
Writing of the flash requires a few minutes. Please do not interrupt or reboot
during this time, as it may corrupt the Flash.
5
Reboot the system.
6
Verify the firmware has been updated using the following command.
nxflash -i NX_NIC --info
7
Verify the MAC address displayed matches the one printed on the card.
5.3
Linux Firmware Updates
The following steps are used for updating the Linux OS firmware.
1
Run the following command from the bin directory of the driver installation:
nxflash -i eth[n] -u
2
Reboot the system.
5.3.1
Linux Firmware Update (TAR Format)
The following steps are used for Flashing the Linux firmware in TAR format.