background image

NTI UNIMUX SERIES USB KVM SWITCH 

 

13

 

DIP SWITCH 

UNIT ADDRESS 

   8    

   7   

   6   

  5  

   

OFF 

OFF 

OFF 

OFF 

0 (not valid) 

OFF 

OFF 

OFF 

ON   

1   (default) 

OFF OFF 

ON OFF 2 

OFF OFF 

ON ON 

 3 

OFF ON OFF OFF 4 
OFF ON OFF ON  5 
OFF ON ON OFF 6 
OFF ON ON ON  7 
ON OFF 

OFF 

OFF 

ON OFF 

OFF 

ON 9 

ON OFF 

ON OFF 

10 

ON OFF 

ON ON 11 

ON ON 

OFF 

OFF 

12 

ON ON 

OFF 

ON 13 

ON ON 

ON OFF 

14 

ON ON 

ON ON 15 

Note:  Pin 4 on the RS232 dip switch is not used. 

 

In order to connect multiple switches (up to 15) with RS232 connections to the same CPU, an NTI Matrix-Y-1 cable must be used.  
Connect the Matrix-Y-1 cable between the RJ45-to-DB9 serial adapter (provided with the RS232 option) and the CPU as shown in 
Fig. 11.     

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

                                                          

                                            Figure 11- RS232 connection with Matrix-Y-1 cable  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  

                                                                                                Figure 12- Pinout of Matrix-Y-1 cable 

 

(Unit #1)

(Source)

2

3

3

3

5

5

5

2

2

7
8
1
4
6

Jumper

Jumpers

Not connected to 
source connector

(Unit #2)

9D Female

9D Male

9D Male

Wiring Schematic of Matrix-Y-1 cable

Note: The "loop back" RS232 dip switch (RS232 dip 
switch 1) should be ON for each unit in the chain.  

NTI

SWITCH

CPU

RS232

First Unit

NTI

SWITCH

RS232

NTI

SWITCH

RS232

Second Unit

Last Unit

RS232 
Serial Port

Matrix-Y-1

Matrix-Y-1

Matrix-Y-1

RJ45
TO DB9
SERIAL
ADAPTER

RJ45
TO DB9
SERIAL
ADAPTER

RJ45
TO DB9
SERIAL
ADAPTER

CAT5 CABLE

CAT5 CABLE

CAT5 CABLE

Note: The maximum combined 
RS232 cable length between the 
CPU and any NTI switch cannot 
exceed 15 feet.  

Содержание NTI High Density DVI USB KVM Switch UNIMUX-DVI-x

Страница 1: ...04 2008 UNIMUX DVI x USB DVI KVM Switch Installation and Operation Manual UNIMUXTM Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www network...

Страница 2: ...c 1275 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in...

Страница 3: ...sta 15 SerTest RS232 Interface Test Program 15 Main Options 15 KEYBOARD FEATURES 17 Keyboard To Computer Translation 17 Translation Capabilities 17 Translation Tables 17 International Sun Keyboards 18...

Страница 4: ...User Input Devices Supported USB keyboard with Windows layout USB keyboard with SUN layout USB keyboard with MAC layout USB Mouse up to 3 buttons USB IntelliMouse scrollwheel USB Hub Mouse Trak track...

Страница 5: ...Technologies Inc by calling 800 742 8324 800 RGB TECH in the US and Canada or 330 562 7070 worldwide DEFINITIONS USB Composite Device A USB device that contains multiple endpoints each representing i...

Страница 6: ...switch address when RS232 is used 7 MONITOR HDMI Type A female connector for connection of the user DVI video monitor 8 5VDC power input connector for attachment of the AC adapter 9 RS232 optional RJ...

Страница 7: ...holes in the sides of the NTI switch Tighten the screws securely Figure 1 Secure rackmount ears to switch 2 Install 4 captive nuts not supplied to the rack in locations that line up with the holes in...

Страница 8: ...ymbol on the front of the UNIMUX 4 Connect the male USB type A connector on the mouse cable to the remaining USB type A female connector labeled with the USB symbol on the front of the UNIMUX Figure 4...

Страница 9: ...U 2 and VIDEO 2 connectors etc Figure 5 Connect each CPU 7 Connect the AC adapter to the UNIMUX See Fig 6 below Figure 6 Connect the AC adapter Rear View of UNIMUX DVI 8 CPU 1 CPU 2 CPU 3 CPU 4 CPU 5...

Страница 10: ...connect the adapter to the RS232 port on the control terminal Follow the instruction under RS232 Control on page 12 for configuration and use of the RS232 control feature Figure 7 Connect RS232 contro...

Страница 11: ...A female ports See Features and Functions on page 3 item 4 A USB hub single or multi port can be used provided only USB input devices are plugged into it Only a USB Windows or SUN keyboard or USB mou...

Страница 12: ...ctly the CPU to which the user is connected through the UNIMUX Keyboard Control Keyboard control of the UNIMUX can be achieved using Command Mode below The keyboard can be used to control all function...

Страница 13: ...t use the Backspace key Normal Mode When all of the UNIMUX mode LEDs are OFF the user is in Normal Mode controlling the CPU to which the user is connected through the UNIMUX No Sun Sleep Mode Note It...

Страница 14: ...elgian 15 Japan Katakana 28 Swiss German 03 Canadian Bilingual 16 Korean 29 Switzerland 04 Canadian French 17 Latin American 30 Taiwan 05 Czech Republic 18 Netherlands Dutch 31 Turkish 06 Danish 19 No...

Страница 15: ...nsmit data RXD at host 7 No connection 8 No connection A 5 foot patch cable and two adapters RJ45 to DB9 and RJ45 to DB25 have been provided for connection to most CPUs see page 7 Baud Rate The baud r...

Страница 16: ...erial adapter provided with the RS232 option and the CPU as shown in Fig 11 Figure 11 RS232 connection with Matrix Y 1 cable Figure 12 Pinout of Matrix Y 1 cable Unit 1 Source 2 3 3 3 5 5 5 2 2 7 8 1...

Страница 17: ...CR IP CR Read Connection For Output User Port to Input CPU Port RS SW CR Internal Reset RU SW CR IP OP CR Read Unit Size SS SW 00 CR Disable Autostatus feature see below SS SW 01 CR Enable Autostatus...

Страница 18: ...Test Program This software allows a user to test the functions of an NTI server switch matrix switch or Multi user Multi platform Single user switch RS232 interface The SerTest program is automaticall...

Страница 19: ...ns into switch memory bank command for all switches h Restore All Units I O Connections from Units Memory not applicable to this model restore the connections from switch memory bank command for all s...

Страница 20: ...nality Full functionality except Application Key Apple Pro Keyboard Extra keys emulation Extra Keys not supported Eject Mute Volume Volume Full functionality Sun Mouse Full functionality Full function...

Страница 21: ...et the UNIMUX to indicate the international keyboard identification number to the CPU by following the instruction on page 11 Enter Enter Ctrl Shift Shift Caps Lock Tab Esc Ctrl Alt Backspace Num Lock...

Страница 22: ...chaining 12 definitions 2 devices supported 1 features 3 front panel control 9 Installation 5 international keyboard layouts 18 Keyboard control 9 keyboard features 17 keyboard translation 17 limitat...

Отзывы: