Command Protocol   

RS232 commands supported by the unit are defined below. All command strings should be terminated with a <CR> (carriage 
return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the 
command definitions.  All characters in the command string should be upper case, and all numbers below 10 should have a 
leading 0 (ex: 1 = 01).   As command strings are sent, the inner character delay cannot exceed 500 milliseconds.    
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                Figure 13- RS232 Communication Illustrated 

 
Note: To use this command protocol, the user is required to write a program that will send an entire command string all 
at once, not character by character.  Programs that send one character at a time (such as HyperTerminal) cannot be used 
to control the UNIMUX.   Alternatively, the user may use the NTI Switch Control Program or SerTest to control the 
UNIMUX via RS232 (see page 15).   

 

Legend

:     (All numbers must be two digits) 

 
SW 

Switch (01-15) (Unit Address) 

OP 

Output (User) Port (01) 

IP 

Input (CPU) Port (01-MAXINPUTS) 

<CR>  : 

Carriage Return (Hex 0xD) 

 
Note: For units with one output (user) port, use 01 for the output selection. 

 

Command Definitions 

Command String 

Good Response 

Description 

CS SW,IP,OP 

*<CR> 

Connect Output (User) Port  To specific Input (CPU) Port 

RO SW,OP 

*<CR>IP<CR> 

Read Connection For Output  (User) Port to Input (CPU) Port 

RS SW 

*<CR> 

Internal Reset 

RU SW 

*<CR>IP,OP<CR> 

Read Unit Size 

SS SW,00 

*<CR> 

Disable Autostatus feature (see below) 

SS SW,01 

*<CR> 

Enable Autostatus feature (see below) 

GO SW,OP 

*<CR>go SW,OP:IP<CR> 

Read connection of a Output (User) Port  to Input (CPU) Port 
(different response format than RO command) 

GM SW,00 

*<CR>go OP,IP (all ports)<CR> 

Read connection matrix of all Output (User) ports 

 
If the first field is not a known command (as listed above) or SW field is different from the unit address programmed at the dip 
switch (page 12), the command will be ignored.  If the SW field corresponds to the unit address, but if the syntax is wrong after 
this field, the switch will answer with a bad response  ?<CR>. 
 

Autostatus 

When Autostatus is enabled, any output (user) -to-input (CPU) connection change in the UNIMUX will cause an Autostatus 
message to be sent via RS232 to the administrator.     The format of the message would be "pc SW,OP:IP<CR>" 
 
Example of an Autostatus message: 

 

  

pc 01,01:04<CR>           

 

which means  "At the switch with unit address 01,  the output (User) (01) has changed connection to input (CPU) port 04."   
 

Note:  An Autostatus message to the administrator will be delayed by any RS232 traffic being received by the switch 
from the administrator.       

 

By default,  Autostatus is disabled and must be manually enabled.   

 
 

CS 01,01,03<CR>

CS 01,01,03<CR>

(COMMAND RECEIVED)

(RESPOND)

* <CR>

(COMMAND SENT)

(RESPONSE RECEIVED)

CS 01,01,03<CR>
* <CR>

CPU 

SWITCH AT UNIT ADDRESS 01

RS232

RS232

(ECHO)

CS 01,01,03<CR>

Содержание NTI High Density DVI USB KVM Switch UNIMUX-DVI-x

Страница 1: ...04 2008 UNIMUX DVI x USB DVI KVM Switch Installation and Operation Manual UNIMUXTM Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www network...

Страница 2: ...c 1275 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in...

Страница 3: ...sta 15 SerTest RS232 Interface Test Program 15 Main Options 15 KEYBOARD FEATURES 17 Keyboard To Computer Translation 17 Translation Capabilities 17 Translation Tables 17 International Sun Keyboards 18...

Страница 4: ...User Input Devices Supported USB keyboard with Windows layout USB keyboard with SUN layout USB keyboard with MAC layout USB Mouse up to 3 buttons USB IntelliMouse scrollwheel USB Hub Mouse Trak track...

Страница 5: ...Technologies Inc by calling 800 742 8324 800 RGB TECH in the US and Canada or 330 562 7070 worldwide DEFINITIONS USB Composite Device A USB device that contains multiple endpoints each representing i...

Страница 6: ...switch address when RS232 is used 7 MONITOR HDMI Type A female connector for connection of the user DVI video monitor 8 5VDC power input connector for attachment of the AC adapter 9 RS232 optional RJ...

Страница 7: ...holes in the sides of the NTI switch Tighten the screws securely Figure 1 Secure rackmount ears to switch 2 Install 4 captive nuts not supplied to the rack in locations that line up with the holes in...

Страница 8: ...ymbol on the front of the UNIMUX 4 Connect the male USB type A connector on the mouse cable to the remaining USB type A female connector labeled with the USB symbol on the front of the UNIMUX Figure 4...

Страница 9: ...U 2 and VIDEO 2 connectors etc Figure 5 Connect each CPU 7 Connect the AC adapter to the UNIMUX See Fig 6 below Figure 6 Connect the AC adapter Rear View of UNIMUX DVI 8 CPU 1 CPU 2 CPU 3 CPU 4 CPU 5...

Страница 10: ...connect the adapter to the RS232 port on the control terminal Follow the instruction under RS232 Control on page 12 for configuration and use of the RS232 control feature Figure 7 Connect RS232 contro...

Страница 11: ...A female ports See Features and Functions on page 3 item 4 A USB hub single or multi port can be used provided only USB input devices are plugged into it Only a USB Windows or SUN keyboard or USB mou...

Страница 12: ...ctly the CPU to which the user is connected through the UNIMUX Keyboard Control Keyboard control of the UNIMUX can be achieved using Command Mode below The keyboard can be used to control all function...

Страница 13: ...t use the Backspace key Normal Mode When all of the UNIMUX mode LEDs are OFF the user is in Normal Mode controlling the CPU to which the user is connected through the UNIMUX No Sun Sleep Mode Note It...

Страница 14: ...elgian 15 Japan Katakana 28 Swiss German 03 Canadian Bilingual 16 Korean 29 Switzerland 04 Canadian French 17 Latin American 30 Taiwan 05 Czech Republic 18 Netherlands Dutch 31 Turkish 06 Danish 19 No...

Страница 15: ...nsmit data RXD at host 7 No connection 8 No connection A 5 foot patch cable and two adapters RJ45 to DB9 and RJ45 to DB25 have been provided for connection to most CPUs see page 7 Baud Rate The baud r...

Страница 16: ...erial adapter provided with the RS232 option and the CPU as shown in Fig 11 Figure 11 RS232 connection with Matrix Y 1 cable Figure 12 Pinout of Matrix Y 1 cable Unit 1 Source 2 3 3 3 5 5 5 2 2 7 8 1...

Страница 17: ...CR IP CR Read Connection For Output User Port to Input CPU Port RS SW CR Internal Reset RU SW CR IP OP CR Read Unit Size SS SW 00 CR Disable Autostatus feature see below SS SW 01 CR Enable Autostatus...

Страница 18: ...Test Program This software allows a user to test the functions of an NTI server switch matrix switch or Multi user Multi platform Single user switch RS232 interface The SerTest program is automaticall...

Страница 19: ...ns into switch memory bank command for all switches h Restore All Units I O Connections from Units Memory not applicable to this model restore the connections from switch memory bank command for all s...

Страница 20: ...nality Full functionality except Application Key Apple Pro Keyboard Extra keys emulation Extra Keys not supported Eject Mute Volume Volume Full functionality Sun Mouse Full functionality Full function...

Страница 21: ...et the UNIMUX to indicate the international keyboard identification number to the CPU by following the instruction on page 11 Enter Enter Ctrl Shift Shift Caps Lock Tab Esc Ctrl Alt Backspace Num Lock...

Страница 22: ...chaining 12 definitions 2 devices supported 1 features 3 front panel control 9 Installation 5 international keyboard layouts 18 Keyboard control 9 keyboard features 17 keyboard translation 17 limitat...

Отзывы: