background image

 

 

3. Product Character 

 

Fully IEEE 802.15.4 compliant (ZigBee Pro) 

 

Utilizes 2.4GHz ISM band, up to 16 channels 

 

Wireless transmission is up to 200 meters linear distance in open field     

 

Simple operation and device configuration 

 

Lithium rechargeable battery   

4.

 

Setting up   

4.1 Turn on / turn off device

 

In the "OFF" state, press the "Binding button" for 3 seconds till device vibrates once prompted, after releasing the 

button,  the device  goes  into the "ON"  state. If the device has not been added to the Internet, the device will 

automatically start searching for the Internet. If there is no Internet access, the device will return to the "OFF" state. 

If the device has found the network or has been to the Internet, it will remain "ON".   

In the "ON" state, long press "Binding key" for 15 seconds (the indicator flashes one time on 2nd , 10th second), 

the device will prompt by vibration at 15th second, and release the button; the device will vibrate once to enter the 

" OFF" state.   

 

Note: Power off Z307 when not in use is recommended 

 

4.2 Join to the Network

 

In order for the Z307 to communicate with the ZigBee network, it needs to be added to the ZigBee network first. 

Operations are as follows: 

 Enable permit-join function of coordinator or router in the same channel with Z307. 

 Press “Binding Key”for 3 seconds to make the Z307 enter "power-on" state. The device will then actively look for 

the network and request to join the network of the channel where it is located. The network indicator flashes once to 

prompt each matched network searching. 

 If joining to the network is successful, the network indicator flashes 5 times, or no action light. If the    time is out 

to join in the network (about 3min), then it returns to the "off" state. To request joining to network, just repeat the first 

two steps. 

Note: During joining network process of Z307, please ensure that the coordinator and router on the network are in 

the power supply status until the device completes the registration. 

 

Содержание Z307

Страница 1: ...Z307 WirelessTM Wireless Fall Sensor Wireless Rechargeable Fall Sensor User Manual Software V4 0 Hardware V1 2...

Страница 2: ...Automatic Zone Registration enrollment 4 4 4 Emergency and Position System 4 4 5 Turn on Permit join Function 5 4 6 Activate the Device 5 4 7 Low power Notification 5 4 8 Restore to Factory Setting 5...

Страница 3: ...This CIE would then instruct other devices in the network to sound or silent alarm with light strobe Z307 acts as an end device in the network which does not perform permit join other devices to join...

Страница 4: ...d and release the button the device will vibrate once to enter the OFF state Note Power off Z307 when not in use is recommended 4 2 Join to the Network In order for the Z307 to communicate with the Zi...

Страница 5: ...the event of emergency the user may press the emergency button once the device vibrates once while it sends alarm signal to the security system for strobe light or siren alert Fall Detect When the wea...

Страница 6: ...roadcast its own short address and IEEE address Z307 will stay active for 2 minutes Note turn on interval after powering on is 5 min by default setting 4 7 Low power Notification The operating voltage...

Страница 7: ...d to normal operating status To prevent this unwanted power consumption we recommend that users manually power off the device 4 10 Battery Charging The device is built in 3 7V lithium rechargeable bat...

Страница 8: ...rance 5 ZigBee Description 1 End Point s 0x01 2 Device ID IAS Zone 0x0402 3 Cluster ID which EndPoint supports Status indicator red Network indicator green A201 Infrared sensor A201Charging indicator...

Страница 9: ...bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 53 O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xff Read only 20 O 0x0004 ManufacturerName Characte...

Страница 10: ...information Click the icon to enter the state of Figure 5 2 Fig 5 1 Fig 5 2 2 Click the red box in Figure 5 2 above the settings section configure whether to open the alarm sound Click to enter the c...

Страница 11: ...10 3 When an alarm occurs the warning message shown in FIG 5 5 Fig 5 5 7 Related Devices A201 Wireless Charger A201 Infrared sensor A201Charging indicator DC power input 5V...

Страница 12: ...and causing the housing to deform Do not use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that i...

Отзывы: