background image

 

 

11 

 

Z302C 

Wireless Window Door Sensor and Wireless Glass Break Sensor 

  

    Z302D 

Wireless Panic Button 

  

  Z201B 

ZigBee HA Coordinator with CIE 

 

8. Important Maintenance Instructions 

As the device is not water proof it is recommended to keep the device in a dry place. Liquid and heavy moisture 

contains minerals that may oxidize the electronic circuitry. In case of liquid spill, please leave the device to 

completely dry before storing or using. 

 

 

Do not use or store the device in a dusty area. Dust may cause electronic parts to destroy. 

 

Do not use or store the device in an over heated place. Store in a hotter temperature than the suggested 

maximum temperature may shorten the life span of the device; and may damage the battery and causing the 

housing to deform. 

 

Do not use or store the device in a very cold place than the suggested minimum temperature. The water can be 

condensed inside the device when moving to an area that is higher in temperature. This can severely damage the 

PCB board and circuitry. This may shorten the life span of the device; damage the battery and cause the housing to 

deform. 

 

Do not throw or strongly vibrate the device. This may damage connectivity of the electronic parts and other 

sensitive components on the PCB board. 

 

Do not use any strong chemical or washing to cleanse the device. 

 

Do not use any coloring materials on any removable parts which my cause poor connections and may keep the 

device from function properly. 

 

All the above applies to the purchased products, battery and other packaged items. If any unusable or damaged 

items are found please return the product to your nearest authorized repairing center. 

 

 

 

Содержание Z307

Страница 1: ...Z307 WirelessTM Wireless Fall Sensor Wireless Rechargeable Fall Sensor User Manual Software V4 0 Hardware V1 2...

Страница 2: ...Automatic Zone Registration enrollment 4 4 4 Emergency and Position System 4 4 5 Turn on Permit join Function 5 4 6 Activate the Device 5 4 7 Low power Notification 5 4 8 Restore to Factory Setting 5...

Страница 3: ...This CIE would then instruct other devices in the network to sound or silent alarm with light strobe Z307 acts as an end device in the network which does not perform permit join other devices to join...

Страница 4: ...d and release the button the device will vibrate once to enter the OFF state Note Power off Z307 when not in use is recommended 4 2 Join to the Network In order for the Z307 to communicate with the Zi...

Страница 5: ...the event of emergency the user may press the emergency button once the device vibrates once while it sends alarm signal to the security system for strobe light or siren alert Fall Detect When the wea...

Страница 6: ...roadcast its own short address and IEEE address Z307 will stay active for 2 minutes Note turn on interval after powering on is 5 min by default setting 4 7 Low power Notification The operating voltage...

Страница 7: ...d to normal operating status To prevent this unwanted power consumption we recommend that users manually power off the device 4 10 Battery Charging The device is built in 3 7V lithium rechargeable bat...

Страница 8: ...rance 5 ZigBee Description 1 End Point s 0x01 2 Device ID IAS Zone 0x0402 3 Cluster ID which EndPoint supports Status indicator red Network indicator green A201 Infrared sensor A201Charging indicator...

Страница 9: ...bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 53 O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xff Read only 20 O 0x0004 ManufacturerName Characte...

Страница 10: ...information Click the icon to enter the state of Figure 5 2 Fig 5 1 Fig 5 2 2 Click the red box in Figure 5 2 above the settings section configure whether to open the alarm sound Click to enter the c...

Страница 11: ...10 3 When an alarm occurs the warning message shown in FIG 5 5 Fig 5 5 7 Related Devices A201 Wireless Charger A201 Infrared sensor A201Charging indicator DC power input 5V...

Страница 12: ...and causing the housing to deform Do not use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that i...

Отзывы: