5
Report configuration example:
(1) Report configuration parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, TemperatureChange = 1
°
C, illuminance = 100lux
Downlink: 0103003C003C0100640064
Devices return:
8103000000000000000000 (the configuration is successful)
8103010000000000000000 (the configuration is failed)
(2) Read device configuration parameters
Downlink: 0203000000000000000000
Devices return:
8203003C003C0100640064 (current device configuration parameters)
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime
MaxTime
S
leeping(MinTime)
S
leeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BtteryVoltageChange value.
Example#2
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
S
leeping(MinTime)
sleeping
sleeping
sleeping
0H
15
th
M
30
th
M
45
th
M
1H
2H
Description
Device
CmdID
DeviceTyp
e
NetvoxPayLoadData
ConfigReportReq
RB11E
0x01
0x03
MinTime(2b
ytes Unit:s)
MaxTime(2byt
es Unit:s)
BatteryChange(1
byte Unit:0.1v)
TemperatureC
hange(2byte
Unit:0.01
℃
)
illuminance
(
2byte Unit:
1Lux
)
ConfigReportRsp
0x81
Status(0x00_
success)
Reserved (8Bytes,Fixed 0x00)
ReadConfigReport
Req
0x02
Reserved (9Bytes,Fixed 0x00)
ReadConfigReport
Rsp
0x82
MinTime(2b
ytes Unit:s)
MaxTime(2byt
es Unit:s)
BatteryChange(1
byte Unit:0.1v)
TemperatureC
hange(2byte
Unit:0.01
℃
)
illuminance
Change
(
2byte
Unit: 1Lux
)
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report
Wakes up
and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORTS
2.8V
Wakes up and collects
data
REPORT 2.8V
Wake up and collects data
REPORTS 2.5V
Wakes up and collects data
REPORTS 2.7V
Wakes up and collects data
REPORTS 2.8V