6.

 

Installation 

6-1 The output value corresponds to wind direction 

Wind direction 

The output value 

North-northeast 

0x0000 

Northeast 

0x0001 

East-northeast 

0x0002 

East 

0x0003 

East-southeast 

0x0004 

Southeast 

0x0005 

South-southeast 

0x0006 

South 

0x0007 

South-southwest 

0x0008 

Southwest 

0x0009 

West-southwest 

0x000A 

West 

0x000B 

West-northwest 

0x000C 

Northwest 

0x000D 

North-northwest 

0x000E 

North 

0x000F 

 

6-2 Installation Method of Wind Direction Sensor 

  Flange installation is adopted. The threaded flange connection makes the lower components of the wind direction sensor 

firmly fixed on the flange plate. Four installation holes of Ø6mm are on the circumference of the chassis. The bolts are used to 

tightly fix the chassis on the bracket to make the whole device keep in the best horizontal position to ensure the accuracy of the 

wind direction data. The flange connection is convenient to use, can withstand greater pressure, and 

ensures that the aviation 

connector is facing the direction of the north.

 

 

 

 

 

 

 

 

 

 

 

 

 

Aviation connector 

NE 

SE 

SW 

NW 

NNE 

ENE 

ESE 

SSE 

SSW 

WSW 

WNW 

NNW 

0x0000 

0x0001 

0x0002 

0x0003 

0x0008 

0x0007 

0x0006 

0x0005 

0x0004 

0x0009 

0x000A 

0x000B 

0x000C 

0x000D 

0x000E 

0x000F 

Содержание R72630

Страница 1: ...0730_R72630_RA0730Y User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict...

Страница 2: ...Set up Instruction 4 5 Data Report 5 6 Installation 7 6 1 The output value of Wind direction corresponds to wind direction 7 6 2 Installation Method of Wind Direction Sensor 7 6 3 Installation 8 6 4 R...

Страница 3: ...distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance...

Страница 4: ...12V adapters R72630 applies solar and rechargeable lithium batteries Simple operation and setting Wind speed wind direction temperature and humidity detection Adopt SX1276 wireless communication modu...

Страница 5: ...search the network The green indicator keeps on for 5 seconds success The green indicator remains off fail Had joined the network Not in the original setting Turn on the device to search the previous...

Страница 6: ...ng to the TxPeriod cycle The particular report cycle is ReportMaxTime or TxPeriod depending on which report cycle was configured last time 6 It would take a while for the sensor to sample and process...

Страница 7: ...00000 configuration failure 2 Read RA0730 device parameter Downlink 0205000000000000000000 Device return 8205001E0E100000000000 device current parameter Description Device CmdI D Device Type NetvoxPay...

Страница 8: ...ed flange connection makes the lower components of the wind direction sensor firmly fixed on the flange plate Four installation holes of 6mm are on the circumference of the chassis The bolts are used...

Страница 9: ...all the washer and the nut in sequence Lock nut till the solar panel is stable and does not shake 3 After adjusting the angle of the solar panel completely lock the nut 4 Connect the top waterproof ca...

Страница 10: ...9 Range of diameter of post for mounting 25 50 mm...

Страница 11: ...000mah The installation of rechargeable lithium battery steps are as follows 1 Remove the four screws around battery cover 2 Insert three 18650 lithium batteries Please make sure the positive and nega...

Страница 12: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...

Отзывы: