5
5.
Data Report
After power on, the device will immediately send a version packet report and two data reports.
The device sends data according to the default configuration before any other configuring.
ReportMaxTime:
RA0730_ RA0730Y is 180s, R72630 is 1800s (subject to original setting)
ReportMinTime: 30s
ReportChange: 0
* The value of the ReportMaxTime should be greater than (
ReportType count *Report10
). (unit: second)
* ReportType count = 2
* The default of EU868 frequency is ReportMinTime=120s, and ReportMaxTime=370s.
Note:
(1) The cycle of the device sending the data report is according to the default.
(2) The interval between two reports must be the MaxTime.
(3) ReportChange is not supported by RA0730_R72630_RA0730Y (Invalid configuration).
The data report is sent according to ReportMaxTime as a cycle (the first data report is the start to the end of a cycle).
(4) Data pocket: wind speed, wind direction, temperature and humidity.
(5) The device also supports the TxPeriod cycle configuration instructions of Cayenne. Therefore, the device can
perform the report according to the TxPeriod cycle. The particular report cycle is ReportMaxTime or TxPeriod
depending on which report cycle was configured last time.
(6) It would take a while for the sensor to sample and process the collected value after pressing the button, please be patient.
The device reported data parsing please refer to
Netvox LoraWAN Application Command document
and
Netvox Lora
Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
Threshold Restore to Factory Setting
Description
RA0730_R72630_RA0730Y has the function of the power-down saving the memory
of network-joining information. This function acquiesces in turn off, that is, it will
rejoin every time when it is power on. If the device is turned on by the
ResumeNetOnOff command, the last network-joining information will be recorded
when every time it is power on. (including saving the network address information
that it is assigned, etc.) If users want to join a new network, the device needs to
perform the original setting, and it will not rejoin the last network.
Operation Method
1.
Press and hold the binding button for 5 seconds and then release
(release the binding button when the LED flashes), and the LED flashes 20 times.
2.
The device automatically restarts to rejoin the network.