6
Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
(
1
)
Configure RA0730 device parameter MinTime = 30s, MaxTime = 3600s (3600>30*2+10)
Downlink: 0105001E0E100000000000
Device returns:
8105000000000000000000 (configuration success)
8105010000000000000000 (configuration failure)
(
2
)
Read RA0730 device parameter
Downlink: 0205000000000000000000
Device return:
8205001E0E100000000000 (device current parameter)
Description
Device
CmdI
D
Device
Type
NetvoxPayLoadData
ConfigRepo
rtReq
RA07 Series
R726 Series
RA07**Y Series
0x01
0x05
0x09
0x0D
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit: s)
Reserved
(5Bytes, Fixed 0x00)
ConfigRepo
rtRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes, Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
Reserved
(5Bytes, Fixed 0x00)