4
4.
Set up Instruction
On/Off
Power On
RA0730 and RA0730Y are connected to DC 12V adapter for power on.
R72630 applies solar and rechargeable lithium batteries.
Turn On
Connect with power on to turn on
Restore to Factory Setting
Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power Off
Disconnect from the power supply
*The engineering test requires to write the engineering testing software separately.
Network Joining
Note
The interval between on and off is suggested to be about 10 seconds to avoid the interference
of capacitor inductance and other energy storage components.
Never Join the Network
Turn on the device to search the network.
The green indicator keeps on for 5 seconds: success.
The green indicator remains off: fail
Had joined the network
(Not in the original setting)
Turn on the device to search the previous network.
The green indicator keeps on for 5 seconds: success.
The green indicator remains off: fail.
Fail to Join the Network
Suggest checking the device registration information on the gateway or consulting your
platform server provider if the device fails to join the network.
Function Key
Press and Hold for 5 Seconds
Restore to the original setting / Turn off
The green indicator flashes 20 times: success
The green indicator remains off: fail
Press once
The device is in the network: the green indicator flashes once and the device sends a data
report
The device is not in the network: the green indicator remains off
Low Voltage Threshold
Low Voltage Threshold
10.5 V