background image

3

Compatible with LoRaWAN

TM

Class A

Frequency hopping spread spectrum technology

Configuration parameters can be configured through third-party software platforms

Data can be read and alerts can be set via SMS text and email (optional)

Applicable to third-party platforms: Actility / ThingPark / TTN / MyDevices /

Cayenne

5. Operation

On/Off

Power on

External 12V power supply

Turn on

Press and hold the function key for 3 seconds till the green indicator flashes once.

Turn off
(Restore to factory setting)

Press and hold the function key for 5 seconds till the green indicator flashes for 20 times.

Power off

Remove power

Note:

1. At 1

st

-5

th

second after power on, the device will be in engineering test mode.

2. Remove and supply the power; the device is at off state by default.
Need turn on the device to use.
3. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.

Network Joining

Never joined the network
(Or at factory setting )

Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail

Had joined the network
(Not at factory setting.)

Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail

Fail to join the network
(when the device is on)

First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used to save power.

Suggest to check the device verification information on the gateway
or consult your platform server provider.

Function Key

Press and hold for 5 seconds

Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail

Press once

The device is in the network: 87+ReceiveData
(ReceiveData is the most recently received data) format packet
The device is not in the network: the green indicator remains off

Содержание R718PA22

Страница 1: ...Model R718PA22 Ultrasonic Fuel Level Meter 0 Ultrasonic Fuel Level Meter User manual...

Страница 2: ...1 Table of Content 1 Statement 2 2 Appearance 2 3 Introduction 2 4 Main Characteristics 2 5 Operation 3 6 Installation 6 7 Important Maintenance Instruction 7...

Страница 3: ...it may measure water gasoline diesel and small medium large capacity storage tanks metal plastic glass material R718PA22 main unit and the ultrasonic liquid level sensor communicate via RS485 interfac...

Страница 4: ...rgy storage components Network Joining Never joined the network Or at factory setting Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator re...

Страница 5: ...nge 0 1v DepthChange 1mm TemperatureChange 1 2 Downlink 019B003C003C0100000000 The device returns 819B000000000000000000 Configuration succeeded 819B010000000000000000 Configuration failed 3 Read devi...

Страница 6: ...49B000000000000000000 The device returns 849B020000000000000000 current device configuration parameters Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V...

Страница 7: ...During the installation test different test liquids water diesel gasoline can be configurated first Wakes up and collects data 3 5V 3 5 3 6 0 1 REPORTS 3 5V Users push the button REPORTS 3 5V Recalcu...

Страница 8: ...can be installed at this detection point 1 means it cannot be installed at this detection point Note When selecting the correct detection point pay attention to the following points a Ensure that the...

Страница 9: ...stroy batteries and deform or melt some plastic parts Do not store in a cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do...