5. Data Report   

 

 

 

 

Data report configuration and sending period are as following: 

 

 

 

 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change

≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0. 

Report 

per Min Interval 

Report 

per Max Interval 

The device will immediately send a version packet report along with an uplink packet including hall sensor status and battery 

voltage. 

 

The device sends data in the default configuration before any configuration is done. 

 

Default setting: 

MaxTime : Max Interval = 60 min = 3600s 

MinTime : Min Interval = 60 min = 3600s 

BatteryChange: 0x01 (0.1V) 

 

Hall sensor status: 

When the magnet closes to the Hall sensor, it will report the status “0” 

    *The distance between the magnet and the Hall sensor is less than 3cm 

When the magnet removes the Hall sensor, it will report the status “1” 

*The distance between the magnet and the Hall sensor is greater than 3 cm 

Note:   

The device report interval will be programmed based on the default firmware which may vary. 

The interval between two reports must be the minimum time. 

 

Please refer Netvox 

LoRaWAN Application Command document

 and 

Netvox Lora Command Resolver

 

http://www.netvox.com.cn:8888/page/index

 to resolve uplink data. 

Содержание R718LB

Страница 1: ...vox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to othe...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 6 6 Installation 9 7 Important Maintenance Instruction 10...

Страница 3: ...rum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equip...

Страница 4: ...onfigurable parameters via third party software platform reading data and setting alarms via SMS text and email optional Available for third party platforms Actility ThingPark TTN MyDevices Cayenne Im...

Страница 5: ...icator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator s...

Страница 6: ...ta report according to Min Interval The device is on but not in the network First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to s...

Страница 7: ...uration is done Default setting MaxTime Max Interval 60 min 3600s MinTime Min Interval 60 min 3600s BatteryChange 0x01 0 1V Hall sensor status When the magnet closes to the Hall sensor it will report...

Страница 8: ...00000000000 Configuration failure 2 Read Configuration Downlink 0225000000000000000000 Response 8225003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoadData Conf...

Страница 9: ...er than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up f...

Страница 10: ...elded box or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 Tear off 3M release paper of Hall sensor and the magnet then attach...

Страница 11: ...rode electronic circuits If the device gets wet please dry it completely Do not use or store the device in dusty or dirty environment It might damage its detachable parts and electronic components Do...

Отзывы: