Sleeping Mode 

The device is on and in the 

network 

Sleeping period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report according 

to Min Interval.   

The device is on but not in   

the network 

First two mins: wake up every 15 seconds to send request. 

After two mins: enter sleeping mode and wake up every 15 minutes to send request. 

Note: Suggest to remove batteries if the device is not used.   

     Suggest to check device verification on gateway. 

Low Voltage Warning 

Low Voltage 

3.2V 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718LB

Страница 1: ...vox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to othe...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 6 6 Installation 9 7 Important Maintenance Instruction 10...

Страница 3: ...rum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equip...

Страница 4: ...onfigurable parameters via third party software platform reading data and setting alarms via SMS text and email optional Available for third party platforms Actility ThingPark TTN MyDevices Cayenne Im...

Страница 5: ...icator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator s...

Страница 6: ...ta report according to Min Interval The device is on but not in the network First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to s...

Страница 7: ...uration is done Default setting MaxTime Max Interval 60 min 3600s MinTime Min Interval 60 min 3600s BatteryChange 0x01 0 1V Hall sensor status When the magnet closes to the Hall sensor it will report...

Страница 8: ...00000000000 Configuration failure 2 Read Configuration Downlink 0225000000000000000000 Response 8225003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoadData Conf...

Страница 9: ...er than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up f...

Страница 10: ...elded box or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 Tear off 3M release paper of Hall sensor and the magnet then attach...

Страница 11: ...rode electronic circuits If the device gets wet please dry it completely Do not use or store the device in dusty or dirty environment It might damage its detachable parts and electronic components Do...

Отзывы: