background image

Netstor  |  31

 

CLI Command

 

======================================================================== 

NAME     SPEED CODE       RPM        STATUS 

Fan 01                      5                        2100                    OK 

Fan 02                      5                        2200                    OK 

Fan 03     Not-Installed 

Fan 04     Not-Installed 

Temperature Element (0x04): 

======================================================================== 

NAME         ID   CT(‘C)   HTW   LTW   OTWarn 

ENC. Temp    01    32      60      5       No 

Chip Temp        02          42            85          5                No 

Voltage Element (0x12): 

======================================================================== 

NAME          VOLT(V)          OVLMT        UVLMT        STATUS 

1V          0.99         1.07      0.94       None 

5V          4.96         5.32      4.63       None 

PowerSupply Element (0x02): 

======================================================================== 

NAME                              STATUS 

PowerSupply01        OK 

PowerSupply02        OK 

AudibleAlarm Element (0x06): 

======================================================================== 

NAME STATUS ALMSTATE 

Audible-Alarm Normal 0 

CLI> 

• SHOWLOGS Command 

The showlogs command allows you to display system event notifications that have been 

generated by 6Gb/s SAS JBOD enclosure. 

Syntax 

CLI>showlogs [DisplayMode(hex, detail, default)] 

Example: 

Содержание 6Gb/s SAS JBOD

Страница 1: ......

Страница 2: ...6Gb s SAS JBOD enclosure Version First Edition Issue Date Jan 2011...

Страница 3: ...s device appears to be malfunctioning contact Netstor Customer Service Do not drop the enclosures or any of its drive modules dropping or mishandling of the enclosure or drive modules may result in a...

Страница 4: ...ing local front panel touch control keypad P12 3 2 Navigation Map of the LCD P13 4 CLI Manager P16 4 1 Expander RS 232C Port Pin Assignment P17 4 2 Start up VT100 Screen P17 4 3 CLI Command P21 HELP C...

Страница 5: ...re the installation of the enclosure verify the items below are included in the package A Enclosure 1 B HDD tray installed in the NS330S 8026 16 C CD containing user s manual 1 D Hard disk drive mount...

Страница 6: ...AS SFF 8088 data cable optional 1 If any of the items listed above is missing or damaged please contact the sales representative 2 Hardware Installation This section gives the layout of the panel and...

Страница 7: ...illuminates it indicates SAS host accesses to NS330S 8026 15 Link LED Green When host port link LED illuminates for 1 second and light off for 3 seconds it indicates one link has connected When host p...

Страница 8: ...Exp out connector 12 SAS Exp in connector 13 SAS Exp out connector 14 Activity LED Blue When activity LED illuminates it indicates SAS host accesses to NS320S 8026 15 Link LED Green When host port li...

Страница 9: ...ure low frequency of RPM or stop 8 Temperature LED Green Normal Red Overheated higher than 55 9 Buzzer mute button 10 Drive presence LED White Power On 11 Activity indicator LED Blue Hard disk drive r...

Страница 10: ...CD display and then enter the password 0000 After you enter the password select Mute Beep and press enter to mute the beep The other way to mute the beep is to click the mute button from the GUI inter...

Страница 11: ...eads of the four screws are level with the drive tray while the trays are attached to the hard disk drives otherwise a screw could take hold of the tray from the bottom side and prevent you to pull th...

Страница 12: ...er card through the SFF 8088 SAS cable Connection between 6Gb s SAS JBOD enclosure and host adapter port is shown below 8 Connecting 6Gb s SAS JBOD enclosure s RS 232 Port optional 6Gb s SAS JBOD encl...

Страница 13: ...her expander ports The SAS RAID controller card or host adapter supports daisy chain The number of the 6Gb s SAS JBOD enclosures that can be supported depends on the RAID controller card or the host a...

Страница 14: ...SAS JBOD enclosure and then connect the other end of the two power cords to the outlets 11 After the two power cords are connected you can switch on 6Gb s SAS JBOD enclosure and the computer 3 LCD Con...

Страница 15: ...m of screens with areas for information status indication or menus The LCD screen displays up to two lines at a time of menu items or other information The initial screen is shown as following Functio...

Страница 16: ...sword protection feature Once the password has been set the user can only monitor and configure 6Gb s SAS JBOD enclosure by providing the correct password The password is used to protect 6Gb s SAS JBO...

Страница 17: ...14 Netstor Navigation Map of the LCD LCM setup option items hierarchical menu...

Страница 18: ...to confirm the input or ready to update a sub item data Esc Exit key to go back to the main selection Set Link Set HDD devices maximun minimun link speed rate the value could be 6 0G 3 0G or 1 5G each...

Страница 19: ...ing the Connection for the RS 232 Port The CLI function can be done by using an ANSI VT 100 compatible terminal emulation program You must complete the appropriate installation procedure before procee...

Страница 20: ...e The controller RJ11 connector pin assignments are defined as below Action Pin Description Pin Description 1 RTS 3 TXD 2 RXD 4 GND 4 2 Start up VT100 Screen By connecting a VT100 compatible terminal...

Страница 21: ...8 Netstor Expander RS 232C Port Pin Assignment Step 1 Open the Taskbar Start Programs Accessories Commmunications Heyper Terminal Heyper Terminal requires version 3 0 or higher Step 2 Open HYPERTRM EX...

Страница 22: ...ep 3 Enter a name you prefer and then click OK Step 4 Select an appropriate connecting port and then click OK Step 5 Configure the port parameter settings and then click OK Bits per second 115200 Data...

Страница 23: ...20 Netstor Expander RS 232C Port Pin Assignment Step 6 Open the file menu and select Properties Step 7 Configure the Connect To setting...

Страница 24: ...nd This section provides detailed information about 6Gb s SAS JBOD enclosure s CLI function All the commands please type in lower case HELP Command This command provides an on line table of contents p...

Страница 25: ...sword has been set the user can only monitor and access 6Gb s SAS JBOD enclosure setting by providing the correct password The password can accept max 8 chars and min 4 chars The manufacture default p...

Страница 26: ...1 5G 9 means 3 0G and 10 means 6 0G PS Pls Save Config Reboot To Take Effect CLI st Example CLI link ArrayDevice Element 0x17 NAME PHY NLR MAX MIN TYPE ADDRESS SLOT 01 0 3 0G 10 8 SAS 5000C500 0D2002D...

Страница 27: ...07 6 6 0G 90 8 SAS 5000C500 17C8FD25 SLOT 08 7 10 8 SLOT 09 8 10 8 SLOT 10 9 10 8 SLOT 11 10 10 8 SLOT 12 11 10 8 CLI st CLI Reboot to take effect CLI link ArrayDevice Element 0x17 NAME PHY NLR MAX M...

Страница 28: ...nnector i j k is the index which range from 0 to 3 According to view from connector side index start from right to left or top to bottom The cable c0 c1 or c2 is view from right to left or start from...

Страница 29: ...Slot 1 2 3 4 5 6 Value 0x00000000000FFC00 Group 2 C1 C2 Slot 7 8 9 10 11 12 13 14 15 16 Value 0x000000000FF003FF Current PHY Group Mode T10 Group 1 C0 C1 C2 Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...

Страница 30: ...d The sys command is used to view the information of 6Gb s SAS JBOD enclosure Typical information includes vendor model name serial unit number expander port number product revision chip name chip rev...

Страница 31: ...06 30 10 Firmware Family 1 Fast Boot No Image Address 0x14100000 SPIN Command The spin command defines the mode of staggering SATA drive spin up function connected to 6Gb s SAS JBOD enclosure This com...

Страница 32: ...d stores system configurations in flash Since all the revised parameter setting is temporarily stored in the working RAM the ST command saves those parameters permanently in flash ROM Syntax CLI st Ex...

Страница 33: ...8 SAS 5000C500 17C8FD25 SLOT 08 7 10 8 SLOT 09 8 10 8 SLOT 10 9 10 8 SLOT 11 10 10 8 SLOT 12 11 10 8 Connector Element 0x19 NAME PHY NLR TYPE STATUS Connector00 16 02 Connector00 17 02 Connector00 18...

Страница 34: ...Element 0x12 NAME VOLT V OVLMT UVLMT STATUS 1V 0 99 1 07 0 94 None 5V 4 96 5 32 4 63 None PowerSupply Element 0x02 NAME STATUS PowerSupply01 OK PowerSupply02 OK AudibleAlarm Element 0x06 NAME STATUS A...

Страница 35: ...sum protocol transmit file to update ROM Region The following procedures are used to update firmware through the RS 232 A Open any UART communication tools like HypeTerminal 115200 n 8 1 B Press any k...

Страница 36: ...r Power cycle again to take effect The following firmware and data are available in the following filename format 1 FW file CODE sas2xfwXXXX fw 2 Data file MFGB mfgdat6gYYYY rom Update 6Gb s SAS JBOD...

Страница 37: ...o beep easily Syntax CLI fan speed code speed code Enter The speed of the four fans will be defined by the speed code you entered Example CLI fan 7 7 The speed of the four fans will be set to the high...