Netstor | 25
CLI Command
SLOT 10 9
10 8
SLOT 11 10
10 8
SLOT 12 11
10 8
• GROUP Command
The group command is used to associate the external port with the devices/phys as one zone
group. The three external cable ports and all devices/phys slots will default associate with
one zone group.
Syntax
gr {dev GroupNo[1..] {ci, cj, ck,..} Start-Index(D) End-Index(D)}
gr {off | [t10 off] }
dev : use drive slot index
GroupNo : groupno start from 1, max 8 groups ci, cj, ck,..: external cable connector. i, j, k,..
is the index which range from 0 to 3. According to view from connector side, index start
from right to left or top to bottom. The cable c0, c1, or c2 is view from right to left or start
from top to bottom.
Start-Index : Start slot index of zone range, [1.. max drive]
End-Index : End slot index of zone range, [1.. max drive]
off : clear the zone group setting.
t10 off : turn T10 mode off.
Example:
CLI>gr
Current PHY Group Mode: T10
Group-1: C0, C1, C2, Slot: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
13, 14, 15, 16
Value: 0x0000000FFFFFFFFF
//Set the cable0 and slot 1 to slot 6 as group 1
CLI>gr dev 1 c0 1 6
New PHY Group Mode: T10
Group-1: C0, Slot: 1, 2, 3, 4, 5, 6
Value: 0x00000000000FFC00