GS716Tv2 and GS724Tv3 Software Administration Manual
2-24
Configuring System Information
v1.0, July 2009
2.
If you make any changes to the page, click
Apply
to apply the new settings to the system.
LLDP Port Settings
Use the LLDP Port Settings page to specify LLDP parameters that are applied to a specific
interface.
To display the LLDP Port Settings page:
1.
Click
System
LLDP
Advanced
LLDP
Port Settings
in the navigation tree.
Figure
2-13
Table
2-15. LLDP Configuration Fields
Field
Description
LLDP Properties
TLV Advertised Interval
Specifies the interval at which frames are transmitted. The default is 30
seconds, and the valid range is 1–32768 seconds.
Hold Multiplier
Specifies multiplier on the transmit interval to assign to Time-to-Live
(TTL). The default is 4, and the range is 2–10.
Reinitializing Delay
Specifies the delay before a reinitialization. The default is 2 seconds,
and the range is 1–10 seconds.
Transmit Delay
Specifies the interval for the transmission of notifications. The default is
5 seconds, and the range is 5–3600 seconds.