Caution: It is extremely important that the values specified for UADD, CU, CHlink, and LPAR
exactly match the values specified in the host system’s device configuration. Failure to do so
will make the devices unusable.
The total number of devices supported on each ESCON interface board is 64. Use this selection button
multiple times until all required device interfaces are defined.
It is possible to define more than 64 devices to satisfy specific configuration requirements (e.g., extra
devices that are only used when needed on backup systems), but care must be taken so that no more than
64 devices are
active
at any point in time. “Over-configuring” the ESCON interfaces with many devices
being used concurrently will have a negative impact on performance.
Remove Channel Interface
This removes a defined channel interface. Prior to selecting this button, provide the following data on
the selection screen:
IFname
the name of the channel interface to stop.
Page
16
Web Browser Interface
MAN-REF-COSW 2.10-19
Содержание NESiGate-CO
Страница 1: ...NESiGate CO NetEx IP Offload Channel to IP Gateway Release 2 10 Reference Manual MAN REF COSW 2 10 19 ...
Страница 7: ...MAN REF COSW 2 10 19 Page vii ...
Страница 9: ...Page 2 Introduction MAN REF COSW 2 10 19 ...
Страница 15: ...Page 8 Customization MAN REF COSW 2 10 19 ...
Страница 49: ...Page 42 Appendix E MAN REF COSW 2 10 19 ...