www.netcommwireless.com
NetComm Wireless Light Industrial M2M Router Plus
11
Interfaces
The following interfaces are available on the NWL-15 router:
Figure 4 - Interfaces
ITEM
DESCRIPTION
RJ45 Ethernet port
Connect one or several devices via a network switch here.
Reset button
Press and hold for less than 5 seconds to reboot to normal mode.
Press and hold for 5 to 15 seconds to reboot to recovery mode.
Press and hold for 15 to 20 seconds to reset the router to factory default settings.
Six-way terminal
Connect power source, ignition and I/O wires here. Power, ignition and I/O wires may be
terminated on the supplied terminal block and connected to a power source. Refer to
the diagram and table under the
Powering the router
section for correct wiring of the
terminal block. Operates in the 8-40V DC range.
Main antenna socket
SMA female connector for main antenna.
Auxiliary antenna socket
SMA female connector for auxiliary antenna (receive diversity).
Mini USB 2.0 OTG port
Provides connectivity for optional external storage or a USB Ethernet dongle. Supplies
up to 0.5A to connected device.
Serial port
Female DB9 port supporting 9-wire RS-232, RS-485 or RS-422 (software selectable).
GPS antenna socket
SMA female connector for an active GPS antenna.
Table 6 – Interfaces