Select the appropriate 

Data Bits 

value from the drop down menu. The data bits are the number of bits in a 

transmitted data package (the recommended setting is 8). 
 

 

 
 
Select the appropriate 

Data Parity 

value

 

from the drop down menu. This feature checks whether data has 

been lost or written over when transmitted between your host computer and your SB72EX (the 
recommended setting is 

None

). 

 

 

 
 
Select the appropriate 

Stop Bits 

value

 

from the drop down menu. The stop bit follows the data and parity 

bits in serial communication. It indicates the end of transmission (the recommended setting is 1). 
 

 

 
 
 
 
 
 
 
 
 
 
 

SB72EX User's Manual,  350030-001 

 

Page 11

 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание SB72EX

Страница 1: ...e t B u r n e r SB72EX User s Manual Revision 1 8 October 8 2009 SB72EX User s Manual 350030 001 Downloaded from Elcodis com electronic components distributor...

Страница 2: ...gs for both Port 0 and Port 1 8 Device Connection Settings UDP mode 9 Serial Configuration for Port 0 and Port 1 10 Serial Port Jumper Configuration 12 SB72EX Pinout Information 13 Click the Return to...

Страница 3: ...wer input jack power on LED and the Ethernet RJ 45 connector Rear view of the SB72EX showing the two RS 232 default configuration serial ports Port 0 is on the left Port 1 is on the right Configuratio...

Страница 4: ...will need to open up your SB72EX case and change the position of the five jumpers Note Please take proper ESD precautions Failure to do so will void your NetBurner Standard Hardware Warranty There are...

Страница 5: ...abling errors reapply power and click the Search Again button Note IP Setup uses a UDP broadcast protocol similar to BOOTP and will not operate through a router 3 If your network supports DHCP factory...

Страница 6: ...nu is selected the SB72EX will obtain its IP Address information automatically including the Subnet Mask Gateway and DNS Server if applicable This is the factory default If Static is selected from the...

Страница 7: ...r settings and Reset to Factory Defaults will restore the factory values Next click on the Advanced Serial Settings link to enter your serial notification information Remember if you are only using on...

Страница 8: ...eck the appropriate box and click the Submit New Settings button to save your settings The message formatting codes are listed below When finished viewing message formatting codes click the Return to...

Страница 9: ...click the Switch to UDP mode link When you are finished with this section click the appropriate button at the bottom Submit New Settings will save your settings and Reset to Factory Defaults will res...

Страница 10: ...the other port s section Select the appropriate Data Port Setting from the drop down menu Remember Port 1 is permanently configured as a RS 232 port Select the appropriate Data Baud Rate from the drop...

Страница 11: ...cks whether data has been lost or written over when transmitted between your host computer and your SB72EX the recommended setting is None Select the appropriate Stop Bits value from the drop down men...

Страница 12: ...e port you can ignore the other port s section Serial Port Jumper Configuration Click the Jumper Configuration link on this page to view Port 0 and Port 1 jumper configuration and pinout information N...

Страница 13: ...SB72EX Pinout Information Click the Return to Setup Page button to return to the Serial section SB72EX User s Manual 350030 001 Page 13 Downloaded from Elcodis com electronic components distributor...

Страница 14: ...nd click the Submit New Settings button to save your user name and password Diagnostics Section Click the Diagnostics link to view the available options To get back to the Networking section click the...

Страница 15: ...P5 type input jack The center is positive and the outer shell in negative Pin Signal Center 7 30VDC Shell GND LEDs Power LED Illuminated while power is applied LED1 on RJ 45 Ethernet speed 10 or 100...

Страница 16: ...0 0 0 to 10 255 255 255 Class B 172 16 0 0 to 172 31 255 255 Class C 192 168 0 0 to 192 168 255 255 If you are doing development on an isolated network you can use the following addresses Set your hos...

Страница 17: ...dow on your host computer 3 Verify everything is connected correctly by executing the command ping 10 1 1 79 and pressing the Enter key on your keyboard You will see a valid ping response Remember to...

Страница 18: ...1 1 79 24 after the prompt and press the Enter key Note This assumes a port number of 24 You must replace this port number with the listening port number that you assigned in the Device Connection Se...

Отзывы: