The I/O module disengages from the chassis and moves about 1/2 inch out of the I/O slot.
c. Remove the I/O module from the chassis by pulling on the pull tabs on the sides of the module face.
Make sure that you keep track of which slot the I/O module was in.
Animation - Replacing an I/O module
Lettered and numbered I/O cam latch
I/O cam latch completely unlocked
6. Install the I/O module into the target slot:
a. Align the I/O module with the edges of the slot.
b. Slide the I/O module into the slot until the lettered and numbered I/O cam latch begins to engage with
the I/O cam pin.
c. Push the I/O cam latch all the way up to lock the module in place.
7. Repeat the remove and install steps to replace additional modules for controller A.
8. If the replacement I/O module is a NIC, cable the module or modules to the data switches.
9. Reboot the node from the LOADER prompt:
bye
10. Give back the node from the partner node.
storage failover giveback -ofnode
target_node_name
11. Enable automatic giveback if it was disabled:
storage failover modify -node local -auto
-giveback true
12. If you added:
If I/O module is a…
Then…
NIC module in slots 3 or 7,
Use the
storage port modify -node *
<node name> -port
*<port name>
-mode network
command for each port.