![NetApp FAS9500 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/netapp/fas9500/fas9500_manual_1669952046.webp)
The controller module devices and ports displayed can be any one or more of the following:
◦
bootmedia is the system booting device.
◦
cna is a Converged Network Adapter or interface not connected to a network or storage device.
◦
fcal is a Fibre Channel-Arbitrated Loop device not connected to a Fibre Channel network.
◦
env is motherboard environmentals.
◦
mem is system memory.
◦
nic is a network interface card.
◦
nvram is nonvolatile RAM.
◦
nvmem is a hybrid of NVRAM and system memory.
◦
sas is a Serial Attached SCSI device not connected to a disk shelf.
4. Run diagnostics as desired.
If you want to run diagnostic
tests on…
Then…
Individual components
a. Clear the status logs:
sldiag device clearstatus
b. Display the available tests for the selected devices:
sldiag
device show -dev dev_name
dev_name can be any one of the ports and devices identified in
the preceding step.
c. Examine the output and, if applicable, select only the tests that
you want to run:
sldiag device modify -dev dev_name
-selection only
-selection only disables all other tests that you do not want to run
for the device.
d. Run the selected tests:
sldiag device run -dev dev_name
After the test is complete, the following message is displayed:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
e. Verify that no tests failed:
sldiag device status -dev
dev_name -long -state failed
System-level diagnostics returns you to the prompt if there are no
test failures, or lists the full status of failures resulting from testing
the component.
44