6. Install the X91148A module into the target slot:
a. Align the X91148A module with the edges of the slot.
b. Slide the X91148A module into the slot until the lettered and numbered I/O cam latch begins to engage
with the I/O cam pin.
c. Push the I/O cam latch all the way up to lock the module in place.
7. Repeat the remove and install steps to replace additional modules for controller A.
8. Cable the module or modules to the data switches.
9. Reboot controller A:
boot_ontap
10. Giveback the node from the partner node:
storage failover giveback -ofnode
target_node_name
11. Enable automatic giveback if it was disabled:
storage failover modify -node local -auto
-giveback true
12. If you added the X91148A module as a NIC module in slots 3 or 7, for networking, use the
storage port
modify -node
node name
-port
port name
-mode network
command for each port.
13. Repeat these steps for controller B.